ZCV3322 / ZCVRB3622
Door and Glass Information
Glass Cleaning
It will be necessary to clean the glass periodically.
During start- up, condensation, which is normal, forms
on the inside of the glass and causes dust, lint etc. to
cling to the glass surface. Also, initial paint curing can
deposit a slight film on the glass. It is therefore
recommended that initially the glass be cleaned two or
three times with non-abrasive common household
glass cleansers and warm water. After that, the glass
should be cleaned two or three times a season
depending on the circumstances.
Glass Replacement
REPLACEMENT GLASS FOR DIRECT VENT UNITS
Model Series
ZCV3622
must use
Tempered Glass
.
Must be 5mm thick.
Model Series
ZDVRB3622
must use
Low-E Tempered
Glass
. Must be 5mm thick.
To replace glass, clean all materials from door frame.
Scrape off old silicone down to metal. Using a high heat
silicone temperature-resistant to 500°F (260°C) apply a
continuous bead of approximately 1/4” to all four sides
of frame and insert glass with new gasket. Frame
should be on flat surface, with a small amount of weight
pressing glass into silicone. Let dry approximately 15 to
20 minutes. The door can be re-installed by reversing
Steps 1 & 2. Use caution when removing broken glass,
wear gloves.
Removal of the Glass Door -ZCV3622, ZCVRB3622
1. Remove the door by unlatching the 2 top latches.
Simply place 2 fingers in the grooves, pull towards
you and lift upwards slightly.
2. Once the top of the door is unlatched, simply pull
outwards and lift upwards to unlatch the bottom.
3. When re-installing the door place the bottom of the
door in first and secure with Top Latch assembly to
the door.
Spring Replacement- ZCV3622, ZCVRB3622
*Over time, spring may need to be replaced if tension is
lost.
1. To remove the top latch, remove the 2 hex screws
that secure it in place. They are located in the
firebox
2. Once all the screws are removed the latches will
slide out of place.
3. There is 1 lock nut per latch. When replacing a
spring, tighten the lock nut until 2 threads are
beyond the locknut. This is critical for proper tension.
⚠
WARNING AND CAUTIONS
Do not clean when the glass is hot.
Do not use abrasive cleaners.
Using a substitute glass will void all product warranties.
Do not strike or abuse glass. Care must be taken to avoid
breakage of the glass.
Do not operate this fireplace without the glass front or with
a broken glass.
Finger Grooves
Spring Part # 36HB-123
Top Hooks
3622 Door Latch
2 Hex Screws inside firebox
Top Door Shield
Safety Screen
24
Содержание marquis SKYLINE ZCVRB3622LPE2
Страница 26: ...Optional Log 4 in raised position LOG 4 26...
Страница 43: ...Gas Conversion for Modulator PART C 43...
Страница 49: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 49...
Страница 50: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 50...
Страница 57: ...Proflame 2 Remote Control 57...
Страница 59: ...59...