NOTE: Make sure power supply is shut off first!
NOTE: When RE-SEALING access panel in the firebox, use
high temp. silicone/millpac.
NOTE: For fan servicing, vacuum and blow lint or dirt build
up from fan blades/motor.
1. Remove glass door assembly and log set if installed.
Be sure to handle logs carefully as they become fragile
after heated.
2. Remove back air shield by unscrewing (4 screws).
3. Remove fan access panel (15 screws). It is located on the
back and bottom right hand corner.
4. Remove the fan from the outer shell (2 hex screws). The
fan needs to be twisted and rotated slightly. The fan’s
motor end will be lifted out first.
5. Reinstall fan, bracket and all necessary components, as
shown below, once completed.
Verify proper operation after servicing.
Fan System – Access Panel/Fan Removal
Fan temperature sensor is located underneath the burner
between the valve and variable speed control. To replace,
disconnect power, remove two wires from sensor, using a
short 1/4” hex screwdriver, remove sensor, and replace.
NOTE: Make sure the wiring harness is mounted to the
bottom of insert, not touching the fire box.
WARNING
Electrical Grounding instructions
This appliance is equipped with a three prong
(grounding) plug for your protection against shock
hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove
the grounding prong from this.
Label all wires prior to disconnecting when servicing
control. Wiring errors can cause improper and
dangerous operation.
Содержание IDV33-IDV36