13
General Glass Information
Door / Door Latch Installation
Glass Cleaning
It will be necessary to clean the glass periodically. During start-up,
condensation, which is normal, forms on the inside of the glass and
causes dust, lint etc. to cling to the glass surface. Also, initial paint
curing can deposit a slight film on the glass. It is therefore recommended
that initially the glass be cleaned two or three times with non-abrasive
common household glass cleansers and warm water. After that, the glass
should be cleaned two or three times a season depending on the
circumstances.
Cautions and Warnings
• Do not clean when the glass is hot.
• The use of substitute glass will void all product warranties.
• Care must be taken to avoid breakage of the glass.
• Do not operate this fireplace without the glass front or with a broken
glass front.
• Do not strike or abuse glass.
• Do not use abrasive cleaners.
Glass Replacement
REPLACEMENT GLASS FOR BOTH DIRECT VENT UNITS
Only Robax ceramic or coated Neaoceram glass may be used for
replacement. Must be minimum 5mm thick.
Removal of the Glass Door
1. To remove, see Door/Door Latch Installation section below.
2. To replace glass, clean all materials from door frame. Using a high
heat silicone (temperature-resistant to 500°F (260°C) apply a bead
of approximately 1/32” to all four sides of frame and insert glass
with new gasket. Frame should be on flat surface, with a small
amount of weight pressing glass into silicone. Let dry approximately
15 to 20 minutes. The door can be re-installed by reversing Step 1
of Removal of Door Instructions.
REMOVAL OF DOOR:
1. Remove door by unlatching the 2 top latches. Simply place two fingers in the grooves. Pull towards yourself and lift upwards
slightly.
2. Once the top of the door is unlatched , simply pull outwards and lift upwards to unlatch the bottom.
3. When re-installing the door place bottom hooks of door in place first.
SPRING REPLACEMENT:
Over time, spring may need to be replaced if tension is lost. Replace spring as follows:
1. To remove a top latch, remove the 2 hex screws that secure it in place. They are located in the firebox.
2. To remove a bottom latch, remove the 4 hex screws located in the firebox bottom beside the burner assembly.
3. Once the screws are all removed, the latches will either fall or slide out of place.
4. There is 1 lock nut per latch. When replacing a spring, tighten the lock nut to a total of 2.531”. This is critical for proper tension.