Gas fired appliances may be used only for supplemental heat and/or decorative purposes and under no circumstances shall they 
provide a primary heat source. 

 

This appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance.  

 
 

NOTE: It is recommended that a Carbon Monoxide (CO) Detector be installed in or near bedrooms and on all levels of your home. 
Place a detector about 15ft [4.5m] outside the room that houses your gas appliance. 

Certified for installation in a bedroom or bed/sitting room. In Canada must be installed with listed millivolt thermostat. 

 In the U.S.A. Thermostats are not permitted for Vented Gas Fireplaces (ANSI Z21.50b-2009 -Decorative). 

  In USA see local codes. 

 

Operations and Maintenance Instructions 

For safe installation and operation note the following: 

• 

The Burner/Log Assembly has been engineered and permanently adjusted for proper flame control. 

• 

Periodically remove the logs from the grate assembly and vacuum any loose particles from the grate and burner areas. See Log 
Placement page to remove logs. Vacuum burner parts and replace logs. 

• 

Never use your gas fireplace as a cooking device. 

• 

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify 
proper operation after servicing. 

Installation Requirements for the Commonwealth of 
Massachusetts 

In the Commonwealth of Massachusetts, the installer or service agent shall be a plumber or gas fitter licensed by the Commonwealth. 

When installed in the Commonwealth of Massachusetts or where applicable codes; the unit shall be installed with a CO detector per the 
requirements listed below. 

1. 

For direct-vent appliances, mechanical-vent heating appliances or domestic hot water equipment, where the bottom of the vent 
terminal and the air intake is installed below four feet above grade the following requirements must be satisfied: 

A. 

If there is not one already present, on each floor level where there are bedroom(s), a carbon monoxide detector and alarm 
shall be placed in the living area outside the bedroom(s). The carbon monoxide detector shall comply with NFPA 720 
(2005 Edition). 

B. 

A carbon monoxide detector shall be located in the room that houses the appliance or equipment and shall: 

 

Be powered by the same electrical circuit as the appliance or equipment such that only one service switch services 
both the appliance and the carbon monoxide detector; 

 

Have battery back-up power; 

 

Meet ANSI./UL 2034 Standards and comply with NFPA 720 (2005 Edition); and 

     Have been approved and listed by a Nationally Recognized Testing Laboratory as recognized under 527 CMR. 

C. 

A Product-approved vent terminal must be used, and if applicable, a Product-approved air intake must be used. 
Installation shall be in strict compliance with the manufacturer’s instructions. A copy of the installation instructions shall 
remain with the appliance or equipment at the completion of the installation. 

D. 

A metal or plastic identification plate shall be mounted at the exterior of the building, four feet directly above the location of 
vent terminal. The plate shall be of sufficient size to be easily read from a distance of eight feet away, and read “Gas Vent 
Directly Below”. 

2. 

For direct-vent appliances, mechanical-vent heating appliances or domestic hot water equipment where the bottom of the vent 
terminal and the air intake is installed above four feet above grade the following requirements must be satisfied: 

A. 

If there is not one already present, on each floor level where there are bedroom(s), a carbon monoxide detector and alarm 
shall be placed in the living area outside the bedroom(s). The carbon monoxide detector shall comply with NFPA 720 
(2005 Edition). 

B. 

 A carbon monoxide detector shall: 

 

Be located in the room that houses the appliance or equipment; 

 

Be either hard-wired or battery powered or both; and 

 

Shall comply with NFPA 720 (2005 Edition). 

A Product-approved vent terminal must be used, and if applicable, a Product-approved air intake must be used. Installation shall be in 
strict compliance with the manufacturer instructions. A copy of the installation instructions shall remain with the appliance or equipment 
at the completion of the installation. 

 

For the state of Massachusetts a 

T-handle gas shut-off valve

 must be used on a gas appliance. This T-handle gas shut-off valve must be listed and 

approved by the state of Massachusetts. This is in reference to the state of Massachusetts state code CMR238. 

 

5

Содержание FV200NE

Страница 1: ...upplier call the fire department Installation Instructions Model Number FV200 FV200P Free Standing Vented Gas Stove Stock s FV200N FV200LP FV200PN FV200PLP FV200NE FV200LPE FV200PNE FV200PLPE are Cert...

Страница 2: ...sed with the installations e g marble tile and the adhesives used to adhere this product to the walls can react with heat and cause odours It is recommended that you burn your gas fireplace or stove f...

Страница 3: ...ructions 8 9 General Glass Information 9 10 Installation Of Brick Panel Kit 10 Installation Instructions for LOGC200 11 Optional Fan Kit Installation 12 Millivolt System Lighting and Burner Control 13...

Страница 4: ...the appliance 15 Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent...

Страница 5: ...A 720 2005 Edition B A carbon monoxide detector shall be located in the room that houses the appliance or equipment and shall Be powered by the same electrical circuit as the appliance or equipment su...

Страница 6: ...B Vent Manufacturer Installation Instruction Chart The unit should be placed on a hard stable surface The appliance may be installed directly on carpeting tile or other combustible material with no ad...

Страница 7: ...IG 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any pressure testing of the gas supply piping system at test pressures equa...

Страница 8: ...eries Children and adults should be alerted to the hazards of high surface temperatures of this appliance and should stay away to avoid burns or ignition of clothing Control compartments burners and a...

Страница 9: ...urner areas This appliance should not be used as drying rack for clothing nor should Christmas stockings or decorations be hung near it Under no circumstances should any solid fuels wood paper cardboa...

Страница 10: ...e reinstalled by reversing Steps 1 2 INSTALLATION OF BRICK PANEL KIT 1 Remove glass door as shown in door removal diagram 2 Place back up to rear of firebox leaving bottom of panel slightly forward fo...

Страница 11: ...n picture and slide Log 3 forward up to the locating tabs 3A 3B Do not place log on top of tabs Step 4 Place Log 4 onto notched areas of Logs 1 3 Step 5 Place Log 5 up against 2nd Grate Bar from the l...

Страница 12: ...it reaches operating temperature in approximately 10 to 15 minutes the fan will turn on The fan can be switched off if desired by turning the switch fully counter clockwise 6 Once the fan has started...

Страница 13: ...MILLIVOLT SYSTEM LIGHTING BURNING CONTROL 14 WARNIING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life 13...

Страница 14: ...itch may be replaced with a wall thermostat or remote Terminals on the valve TPTH and TH are for wiring on off switches remotes or thermostats Recommended Maximum Lead Length Double Wire When Using Wa...

Страница 15: ...oper operation Flame should appear similar to the above picture Conversion Kit Instructions PART A Kit Number Description Pilot Orifice Burner Orifice Brass 1000 255 Brass Nipple Air Shutter Hi Lo Reg...

Страница 16: ...to convert the valve from one type of fuel to the other Step 8 Check for gas leaks around the pilot burner tube and face of valve Step 9 Attach conversion label to label plate on bottom of unit writi...

Страница 17: ...e new injector is proper for the application The injector size is stamped on the side of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG...

Страница 18: ...Gas Conversion for Modulator PART C WARNING WARNING 18...

Страница 19: ...the remote Contrary to this feature is a Manual HI LO Control Knob The Modulating Servo Motor requires the Remote system to be present Backup Battery Pack This component permits the IPI system to oper...

Страница 20: ...ol wiring harness instead of the main IPI harness From the Remote wiring harness use its male plug in connector and connect it to the female plug in in the main IPI harness Now the circuit is complete...

Страница 21: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 21...

Страница 22: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 22...

Страница 23: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 23...

Страница 24: ...ent LIGHTING INSTRUCTIONS 1 STOP Read the above safety information on this label 2 Remove batteries from Receiver and or Battery Backup Pack 3 Turn off all electric power to the fireplace 4 This firep...

Страница 25: ...existing chimney is six 6 inches or larger Four 4 inch single wall or B Vent liquid fuel gas chimney or Flex Gas Liner may be used to adapt existing chimney or liner to stove When installing with B V...

Страница 26: ...t Z80PT Thermostat Programmable Digital Millivolt Wall Mount 1 F80 40 Z1RC Remote Control Millivolt On Off with LED Model I ZART Remote Control Thermostat Millivolt Model K DCHS Remote Control Heatshi...

Страница 27: ...tepper Motor NG 1002 P012si Stepper Motor LP 1002 P016is Hi Lo Regulator NG 1002 P014si Hi Lo Regulator LP CONVERSION KITS 200V CKLP Conversion Kit Liquid Propane FV200LP FV200PLP 200V CKNG Conversion...

Страница 28: ...ge Check generator with millivolt meter Take reading at generator terminals of gas valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Rep...

Страница 29: ...th service or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoe...

Отзывы: