16
VENT INSTALLATION
VENTING INSTRUCTIONS
NOTE: A chimney venting this stove shall not
vent any other appliance.
This appliance may be vented in various types of
applications, 'A' Vent of solid fuel wood burning
chimney. Masonry Clay lining and 'B' Vent liquid
fuel gas chimney. A 90 degree elbow can be
installed directly off the vent of the stove with a
maximum 3 ft. of horizontal before returning
vertical. (See Above Diagram)
NOTE: Four (4) inch is required if existing
chimney is six (6) inches or larger. Four (4)
inch single wall or 'B' Vent liquid fuel gas
chimney or Flex Gas Liner may be used to
adapt existing chimney or liner to stove.
When installing with 'B' Vent liquid fuel gas
chimney install as per 'B' Vent Manufacturer
installation specifications. Horizontal and
vertical, offset vertical or vertical installations
maybe installed.
NOTE: Installation of 'B' Vent must follow 'B'
Vent Manufacturers installation instructions
when being used.
Seal all connections in venting system.
Follow the 'B' Vent chart for horizontal vertical
venting or offset vertical venting. Minimum
vertical venting is 10 ft. maximum 60 ft.
25