Approved for Power Vent PVH58 / PVH58FM
- This appliance is approved for use with Kingsman Horizontal Power Vents -
A Horizontal Power Vent Termination is intended for use where standard venting configurations are not
possible.
Refer to Power Vent Manual for proper installation and use.
•
NOTE:
MODELS EQUIPPPED WITH MILLIVOLT/ STANDING PILOT IGNITION: Downward vertical vent runs are
NOT
permitted.
•
NOTE:
MODELS EQUIPPPED WITH INTERMITTENT PILOT IGNITION (Proflame 1 or Proflame 2): Downward
vertical vent runs are permitted, however, Cold Climate Switch (Standing Pilot Mode) must
NOT
be used.
MQZCVBG34 - Maximum & Minimum Vent Lengths
using Power Vents:
•
Minimum Vent Length
is 4 FT vertical x 6 FT
horizontal with up to 5 elbows.
•
Maximum Vent Length for 5/8 Flex Pipe
is 7FT
vertical x 125FT horizontal with up to 5 elbows.
•
Maximum Vent Length for 5/8 Hard Pipe
is 8FT
vertical x 125FT horizontal with up to 8 elbows.
Units Can be Reduced to 3 x 5” or 4 x 6-5/8” Venting
(A 12 Inch Length of 5/8 M&G Duravent Pipe Must be
Connected to Fireplace Flue First.)
3 x 5” Venting:
-
PVA5835
- Pipe Reducer for
Fireplace
-
PVA3558
- Pipe Increaser for
Termination
4 x 6-
5/8” Venting:
-
ZDVDRA
- Pipe Reducer for
Fireplace
-
ZDVDIA
- Pipe Increaser for
Termination
PVH58
PVH58FM
At Fireplace Flue:
PVA5835
for 3 x 5” Venting
ZDVDRA for 4 x 6-
5/8” Venting
For Power Vent Termination:
PVA3558 for
3 x 5” Venting
ZDVDIA for 4 x 6-
5/8” Venting
5/8
M & G
DURAVENT
PIPE
12”
76