An
Advanced
Programmable
Multifunctional
GSM
Auto
Dialer
Alarm
Panel
In
The
Worldwide!
User Manual
S100Pro
Ver 1.0
Date Issued: 2013-09-01
All rights reserved by King
Pigeon Hi-Tech.Co.,Ltd.
GSM Alarm
Страница 1: ...An Advanced Programmable Multifunctional GSM Auto Dialer GSM Alarm Panel In The Worldwide User Manual S100Pro Ver 1 0 Date Issued 2013 09 01 All rights reserved by King Pigeon Hi Tech Co Ltd GSM Alarm ...
Страница 2: ...he Siren output DD To switch OFF the Siren output EE Inquiry the Status The commands should plus Password the format is Password SMS Command i e if the password is 1234 then you can send 1234AA to arm 1234BB to disarm the AA EE must be Caps Lock This handbook has been designed as a guide to the installation and operation of GSM Alarm System S100Pro Statements contained in the handbook are general ...
Страница 3: ... modes for Stay Away SOS and 24 hours timer to armed or disarmed supports auto dial 6 numbers and send SMS Alarm alert to 4 mobile numbers once alarm occurrence In one word the GSM Alarm System S100Pro includes almost all useful functions and features of the alarm systems in the worldwide markets Also it with innovative and experienced functions and features to meet the required and potential dema...
Страница 4: ...s Break Sensor Magnetic Window Sensor Temperature Sensor Infrared Beam Fence Vibration sensor Siren 4 Mainly Features GSM Frequency Quad Band 850 900 1800 1900Mhz Supports Away Stay or disarmed SOS by remote control or keyboard Supports Away disarmed switch on or off Siren by SMS Commands or smart apps Supports Away Disarmed switch on or off siren listen onsite by call in Automatically send SMS Al...
Страница 5: ...e the alarm finished it will switch off Open automatically This is special for while alarm occurrence to switch on any other warning device Please note the Max is 500Watts 5 1 Alarm Host Diagram The host shall be installed in the centre of the prevent site which could realize best receiving effect from all wireless detectors Please note that keep the host away from large sized metallic objects and...
Страница 6: ...Page 6 of 25 Ver 1 0 A Top Safety and Protection Solution In The Worldwide wire connecting terminal LCD display ...
Страница 7: ...ong ring with the signal five lattice on the screen The signal lights flash every one seconds if the alarm system is good Last please turn on the backup battery switch 6 2 System setting In the state of disarm input 4 digit administrator password by the keypad on the host and press button to confirm You will hear a voice prompt please enter instruction At the same time set indicator is on without ...
Страница 8: ...you will hear remote control coding the indicator is on without flashing Press any button on the wireless remote controller the host makes a long beep and you will hear coding completed indicators goes out indicating the remote controller succeeds in coding The code of next remote controller will be displayed on the LCD screen automatically when coding completed Operating method 21 Ö Notes The sam...
Страница 9: ...host to alarm after the whole deletion In setup state use keypad to input 25 and then press to confirm The host emits a long beep and the defense zone indicator flickers once You will hear a voice prompt delete completed Operating method 25 Ö LCD display 6 11 Zone Attribute Setting Various zone attribute is convenient to decide which detector will be alarmed There are 4 choice 0 Disable This zone ...
Страница 10: ...e zones number Y indicates one defense zone attribute Notes wired defense zone of Z1 is equal to zone of 81 wired defense zone of Z2 is equal to zone of 82 wired defense zone of Z8 is equal to zone of 88 in turn Example zone attribute for defense zone of Z2 is set to Away Armed Operating method 47 Ö 82 Ö 1 Ö LCD display 6 12 Siren Prompt setting In arm or disarm external siren prompt arm or disarm...
Страница 11: ... LCD display 6 15 Alarm Delay Time Setting Alarm delay time setting is that the host will not alarm until delay timeout In setup state press 34 then input delayed time 00 99 seconds finally press to confirm The host makes a long beep A setting completed voice prompt appears Operating method 34 Ö XX Ö XX indicates Alarm delay time unit second Example Detailed operating of 5 seconds alarm delayed ti...
Страница 12: ...setup state use keypad to input 37 and then press to confirm The host will emits a beep and the indicator is on and after 10 seconds countdown recording starts record at 30cm away from the host with moderate tone 10 seconds later the host will make a beep indicating the recording finish and the recorded voice will replay Operating method 37 Ö LCD display Note when you need to change the content of...
Страница 13: ...ting In setup state press 40 then input 0 1 finally press to confirmed The host makes a long beep A setting completed voice prompt appears Operating 40 Ö X Ö X 0 indicates Keypad unlock while Arm Disarm Stay by the keypad will not require enter password X 1 indicates Keypad lock While Arm Disarm Stay by the keypad will require enter password Example Open the keypad lock function Operating 40 Ö 1 Ö...
Страница 14: ...me hour and minute XXYY indicates arming time hour and minute Example set disarming is 8 20 and arming time is 20 30 Operating 42 Ö 0820 Ö 2030 Ö LCD display 6 23 Reset The Settings All telephone number will be deleted automatically when main host reset In setup status first press 43 then press to confirm The host makes a long beep A setting completed voice prompt appears Operating 43 Ö LCD displa...
Страница 15: ...n t inform the 1st SMS Alert Number LCD display 6 27 Clock Setting In setup state use keypad to input 48 then input the last 2 digits AA of the present year the two digits BB of the month the two digits CC of the date The two digits DD of the hour 24 hour system the two digits EE of the minute and finally enter to confirm You will hear a long beep and a voice prompt setting completed Operating 48 ...
Страница 16: ...t number 51 Ö 6 30 The 3rd and 4th SMS Alert Phone Number Setting In setup status enter address No 57 58 then input phone number finally press to confirm The host makes a long beep the signal flashes at the same time You will hear a voice prompt setting completed Operating XX Ö YY YY Ö XX indicates the 3rd and 4th SMS alert number address 57 58 YY YY indicates telephone mobile number set well Exam...
Страница 17: ...ing the outer security Disarmed Except the 24 Hours emergency zones triggered will cause alarm all of the other zones triggered will not cause alarm Usually for maintain or other special requirements 3 Alarm Occurrence 1 When alarm occurrence the S100Pro will send out Alarm SMS Content firstly then automatically dial the authorized numbers one by one if picked up the call the S100Pro will stop to ...
Страница 18: ...while prevent from triggering the indoor detectors which may cause improper warning then you shall select Stay let just part of the detectors work and disable the other parts Press the Stay Button on the keypad LCD display 7 5 Disarm It means to stop the alarm when the host sounds the alarm or makes the alarm system in the state of non warning After disarming even if you trigger the detector the h...
Страница 19: ... every second enter only 1 digit and the host will make di sound to confirm then you can start to enter the next digit otherwise will warning wrong password The password is user password and entered via telephone mobile For wrong password the host gives prompt wrong password please enter password again For correct password the telephone receiver prompts press to arm press to disarm press to monito...
Страница 20: ...ase see below 7 10 SOS for Help Some special cases occur in the family sudden illness for the elderly or children results in first aid in case of sudden fire help is needed in case of housebreaking the alarm is required So please just press the xxxxEE xxxx stands for the user password 4 digits Return SMS Armed or Disarmed AC Power ON or AC Power off Example 1111DD When the Password is 1111 xxxxDD ...
Страница 21: ...ps Test Button press the Test Button then can trigger them The other wireless detectors please reference its user instructions b When the wireless PIR Motion detection is PIR 100B please remember setup the PIR 100B to Test Mode while learning to the S100Pro after learned to the S100Pro then please setup to Normal Mode by change the Black PIN Jumpers in the PCB please see the PIR 100B user manual c...
Страница 22: ...Photoelectric Beams Detector Microwave Dual PIR Detector Gas Leakage Detector Smoke Detector Water leakage overflow detector Necklace Waterproof Panic Button Emergency Button Wireless Signal Repeater 9 Technical specifications Rated Voltage 12VDC 2A Standby current Less than 50mA Working Current Less than 435mA Working temperature 10 60 Storage temperature 20 60 Relative humidity 10 90 No condensa...
Страница 23: ... switch it on after one minute Test this system after another minute or check the settings are correct and the GSM Signals are strong enough 3 If the S100Pro can run and sensors work but cannot send SMS texts please change SIM Card to check it 4 If the problem cannot be solved please contact the distributor or manufacturer 11 Warranty 1 This system is warranted to be free of defects in material an...
Страница 24: ...nsor Alarm Type Installation Place 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 S100Pro Authorized Number Schedule SIMCard Number in the S100Pro ___________________ Auto Dial Phone Number SMS Alert Phone Number SN User Name Phone Number SN User Name Phone Number 1 1 2 2 3 3 4 4 5 User Password 6 Administrator Password Notice Please mark V if for enable and X for disable ...
Страница 25: ...delayed 34 X X 00 99 seconds 12 Telephone Dial up Cycle Times 35 X 13 Remote Call Ring Times 36 X X 0 9 times 14 Change User Password 38 XXXX XXXX 4 digit 15 Change Administrator Password 39 XXXX XXXX 4 digit 16 Keypad Lock Setting 40 X X 1 open X 0 closed 17 Timing Setting 41 X X 1 open time setting function X 0 close time setting function 18 Timing Arm or Disarm Setting 42 XXXX YYYY XXXX arm tim...