5. INSTALLATION

The installation of your osmosis equipment 

should be carried out by a suitably qualified technician. 

Please read carefully the user manual before use and con-

sult with your distributor in case of doubt.

Warning: Since the equipment to be installed will im-

prove the quality of your drinking water, all tools to be 

used in the installation process should be clean, rust 

and grease free. Only use tools, which are specifically de-

signed for membrane pipe cutting. Please keep tools clean 

and disinfect them periodically.

Warning: The installation process should be carried 

out under appropriate hygienic conditions, taking all 

necessary precautions in relation to materials and 

components that will come into contact with water to be 

treated or consumed.

(For further information, please contact your distributor).

Warning: Avoid external contamination of the equip-

ment through improper handling, using gloves, sani-

tising gel and washing hands as often as is necessary 

during the installation process, initial operation and equip-

ment maintenance.

The most common installation location tends to be under 

the kitchen sink unit or in an annexed fitting.

Install the tap, the waste water clamp and entry inlet 

adapter and connect the equipment’s respective connec-

tors (5, 6 and 7). Insert the filter cartridges into their respec-

tive heads after removing them from the packaging, should 

they be supplied separately. Check the corresponding sec-

tion of the Technical Sheet.

Should the system comes with a separate tank, hydrauli-

cally connect it to the filtering equipment via the valve and 

appropriate connectors.

Warning: Some of the installation accessories may 

vary in function of the model and distribution region.

Use the appropriate tools and sealants to ensure that con-

nections do not leak.

Removal of safety plugs (4).

6. INITIAL OPERATION

6.1. MEMBRANE ASSEMBLY

This equipment includes a pre-installed encapsulated 

membrane, thus it does not require any other additional 

handling.

6.2. SANITIZE THE EQUIPMENT

Sanitize the equipment according to the model and proce-

dure indicated by 

Sanitizing Procedure.

In the event of any queries please consult with your distrib-

utor.

6.3. TANK PRESSURE CHECK

With the water inlet stop cock closed and the tank empty;

check the tank pressure, which should be around 0.5 bar  

(8).

6

40mm drain clamp.

5

7

Adapter and inlet valve for 

3/8” connections.

4

8

Содержание ERGO RO BLUE

Страница 1: ...IU Instructions for use Reverse osmosis equipments...

Страница 2: ......

Страница 3: ...IU 5 11 21 29 INDEX 1 USER S MANUAL 2 DATA SHEET SERVICE BOOK 3 TECHNICAL MANUAL 4 SANITISING PROCEDURE...

Страница 4: ......

Страница 5: ...User s Manual UM Reverse osmosis equipments...

Страница 6: ...n the corresponding section of the Technical Manual Warning This equipment IS NOT FIT TO BE USED WITH WATER UNSUITABLE FOR HUMAN CONSUMPTION If the water to be treated comes from a public water supply...

Страница 7: ...sure It is the effect of the water pressure upon the mem brane which makes the reverse osmosis possible Treated water is held in the water tank for its subsequent use Water that is rejected or has ex...

Страница 8: ...e Call the Technical Service Call the Technical Service Check the state of the main inlet valve of the house and the appli ance Check the general power supply If the problem persists please call the T...

Страница 9: ...9 UM 8 NOTES...

Страница 10: ......

Страница 11: ...Data Sheet Service Book DS Reverse osmosis equipments...

Страница 12: ...DS 12...

Страница 13: ...Protection against pressure drops in the supply network EXCLUSIVE FILTERS Exclusive filters ELECTRONIC ADAPTER Higher safety and efficiency SHUT OFF VALVE Basic hydraulic control EQUIPO CON BOMBA ENCA...

Страница 14: ...y vary in function of the type of post filter used by the equipment and or setting of the mixing valve where applicable Technical Information SO PUMP Control type 4 way mechanical valve High pressure...

Страница 15: ...ENCAPSULATED Post filter 1 x GAC 1 x GAC Power supply 24 Vdc 1 1 A Power adapter 100 240 Vac 50 60 Hz 24 Vdc Type of tap Ceramic valve Ceramic valve Production 0 15 lpm 0 17 lpm Without counter pressu...

Страница 16: ...the reverse osmosis process Higher levels of hardness can reduce the service life and correct function of certain components Maximum accumulation in function of entry pressure Flows can vary by up to...

Страница 17: ...membrane which makesthereverseosmosispossible The treated water is held in the water tank for its subsequent use Water that is rejected or has excessive salt or other dis solvedsubstancesisfedtothedr...

Страница 18: ...TAMP OF AUTHORISED TECHNICIAN MAINTENANCE COMPLETE REPAIR SANITATION OTHERS INITIAL OPERATION TECHNICIAN ORDINARY EXTRAORDINARY WARRANTY STAMP TECHNICIAN ORDINARY EXTRAORDINARY WARRANTY STAMP TECHNICI...

Страница 19: ...AN MAINTENANCE COMPLETE REPAIR SANITATION OTHERS INITIAL OPERATION TECHNICIAN ORDINARY EXTRAORDINARY WARRANTY STAMP TECHNICIAN ORDINARY EXTRAORDINARY WARRANTY STAMP TECHNICIAN ORDINARY EXTRAORDINARY W...

Страница 20: ......

Страница 21: ...Technical manual TM Reverse osmosis equipments...

Страница 22: ...d not co ming from a public water supply or from an unknown source a physico chemical and bacteria analysis of the water Should be completed in order to ensure the co rrect purification process and by...

Страница 23: ...partment In the event of the equipment incorporating a mixing sys tem the valve should always be closed during installation and initial operation The mix should be set to the required characteristics...

Страница 24: ...ing hands as often as is necessary during the installation process initial operation and equip ment maintenance The most common installation location tends to be under the kitchen sink unit or in an a...

Страница 25: ...pe of use and specific water con ditions such as extreme turbidity high chlorine levels excessive iron content etc Warning With the aim of guaranteeing the quality of the water supplied by your equipm...

Страница 26: ...your dis tributor In the event of replacing the membrane follow the manu facturer s instructions in relation to handling and sanitizing as appear in the Sanitizing Procedure Warning Use gloves or app...

Страница 27: ...27 TM 8 NOTES...

Страница 28: ......

Страница 29: ...Sanitising procedure SP Reverse osmosis equipments...

Страница 30: ...p 2 Close the tap after making sure that no more water is running out of it Change and wash the filters and the post filter as outlined in the corresponding section of the Technical Manual The sanitiz...

Страница 31: ...lve and the tap must be closed Plug the appliance to the power supply if the model requires a power supply Open the inlet valve and let the appliance start working so it will absorb the hydrogen perox...

Страница 32: ...ly tap and empty the tank Close the tap and open the inlet valve for 1 minute so the tank gets full of tap water Close the inlet valve open the water sup ply tap and empty the tank Repeat this procedu...

Страница 33: ...l Apply the sanitizing spray on the tap nozzle 13 rub the spout and the nozzle with disposable paper towel and do not touch it with bare hands 14 Since sanitizing and rinsing do not either guarantee t...

Страница 34: ...8 NOTES SP 34...

Страница 35: ...8 NOTES SP 35...

Страница 36: ...ERGOROBLUEIU2018 IU...

Отзывы: