14
32
SP
• Unplug the inlet tube from the appliance marked as
"feed-entrada" ( ), connect it to the free connection of
the T-connector mentioned above (see 1 in sketch 11) and
place the dosage housing in between.
• Pour 0.25 litres of hydrogen peroxide into the dosage
housing. Screw the housing properly in its head. The inlet
valve and the tap must be closed.
• Open the inlet valve and let the tap water and the hydro-
gen peroxide from the dosage housing fill the storage tank
of the appliance for 2 minutes. Then close the inlet valve.
• Open the water supply tap for 5 SECONDS to let the hydro-
gen peroxide reach the tap. Do not keep it open for more
than 5 seconds, otherwise the hydrogen peroxide will flow
out of the tap. Close the water supply tap and keep it closed
(12).
• Let the hydrogen peroxide sit inside the appliance for 15
minutes.
OPEN
12
4. RINSING
Rinse the tank with tap water proceeding as follows:
• Open the water supply tap and empty the tank. Close the
tap and open the inlet valve for 1 minute so the tank gets
full of tap water. Close the inlet valve, open the water sup-
ply tap and empty the tank. Repeat this procedure until no
hydrogen peroxide is left inside. Repeat this procedure for
at least 5 times. On this purpose, use strips to detect the
presence of hydrogen peroxide.
• Keep the inlet valve closed and the tank empty, then un-
plug the inlet tube from the T-connector and plug it prop-
erly into the inlet of the appliance. Plug the osmosis water
production tube of the membrane into the T-connector,
where it was initially connected.
• Remove the dosage housing and all accessories that have
been used to sanitize the system. Remove the sanitizing
dosage housing and the manual inlet valve.
• Dry all the parts that may have got wet using a disposable
paper towel.
• Pay special attention to the disinfection of the tap spout.
CARBON
CARBON
INLET
SEDIMENTS
DRAIN
MEMBRANE
TAP
OUTLET
PRODUCTION
Dosage
housing
DRAIN
Dosage
housing
TAP
OUTLET
TANK
POST-FILTER
1
1
CARBON
CARBON
POST-FILTER
PRODUCTION
INLET
SEDIMENTS
TANK
MEMBRANE
10
11
Содержание ERGO RO BLUE
Страница 1: ...IU Instructions for use Reverse osmosis equipments...
Страница 2: ......
Страница 4: ......
Страница 5: ...User s Manual UM Reverse osmosis equipments...
Страница 9: ...9 UM 8 NOTES...
Страница 10: ......
Страница 11: ...Data Sheet Service Book DS Reverse osmosis equipments...
Страница 12: ...DS 12...
Страница 20: ......
Страница 21: ...Technical manual TM Reverse osmosis equipments...
Страница 27: ...27 TM 8 NOTES...
Страница 28: ......
Страница 29: ...Sanitising procedure SP Reverse osmosis equipments...
Страница 34: ...8 NOTES SP 34...
Страница 35: ...8 NOTES SP 35...
Страница 36: ...ERGOROBLUEIU2018 IU...