Limits
© 2011 Kinesys Projects Ltd
the lower limit would be set to 1000mm and the current position would also be set to
1000mm.
The hoist would then be taken out of menu mode so it could be run (This is achieved by
pressing the menu button repeatedly until the menu mode is exited). The hoist could
then be run to its highest position and the position noted (lets say this is 6278mm off the
stage). The Elevation is again put into menu mode and the new value of 6278mm is set
for the upper limit.
It should be noted that an Elevation may have old limits programmed into it and these
may cause movement to stop before the desired position is reached. In this case the
existing limits would need to be opened out.