6.2
‘Drive’ MCB
Figure 20
Drive MCB
The Drive MCB is used to protect three phase power to the internal power
electronics. This MCB does not affect the apexDRIVE control electronics.
If the Drive MCB should trip in to the down position, try to move the lever back up
to restore power. If the MCB immediately trips again this indicates a fault. Switch
over to an alternative apexDRIVE and contact your supplier or Kinesys for support.
WARNING!
DO NOT ATTEMPT TO KEEP AN MCB POWERED ON BY HOLDING THE
LEVER IN THE ON POSITION
6.3 Brake Fuses
Each apexDRIVE is fitted with a 4A aR 10x38mm Fuse (two fuses on 208V
variants) to provide protection for the electromagnetic brakes on the apexHOIST.
Spare fuses are provided in the front mounted fuse holder. The fuse change
process is detailed on page 42.
Figure 21
Brake fuses
WARNING!
ALWAYS REPLACE FUSES WITH SAME TYPE AND RATING.
SPARE FUSES ARE SUPPLIED IN THE ‘BRAKE’ FUSE CARRIER