5 Connections
5.1 Ethernet
The apexDRIVE IN and OUT Ethercon Ethernet connections enable networking of
a number of apexDRIVE units and a Mentor safety controller. The OUT connection
is used when linking more than one drive together to form a system.
Alternatively, depending on application, a DC8 v2 E-stop hub may be used. When
used with an EVO v2 system the OUT connection is not used. EVO mode must be
enabled using the option on the Safety Status screen, refer to page 36.
Ethernet cables must be shielded CAT5e type. Kinesys recommends the use of
Neutrik Ethercon connectors with ProPlex PCCAT5EP cable.
Figure 11
Ethercon connector
Figure 12
Network connection of multiple apexDRIVE
The maximum recommended length of an Ethernet link between units is 90m.
Where possible use single cables and avoid the use of joiners or couplers. Where
couplers are used reduce the maximum length of the link by 5m for each coupler
inserted.
The Ethernet standard states a 100m maximum link length between devices. In
order to extend further than 100m the use of a fibre connection will be required.
Please consult with Kinesys for further details on using a fibre connection with an
apexDRIVE.