background image

To adjust the heat input via the remote handset :-

Press the “up” button to light the main burner and adjust the heat input

to the maximum setting. (6.9kW heat input). If you press and hold the

“down” button it will reduce the heat input to the minimum (3.5kW heat

input) setting, if you keep the button depressed it will turn the main

burner off at this point a clicking noise will be heard from the motor.

Fig. 28

NOTE : The remote control does not light the pilot, it only lights

the main burner when the pilot flame is established and regulates

the heat input between high and low.

d)

Check that the gas pressure is

20.0 mbar (+/- 1.0mbar) 8.0 in w.g.(+/-

0.4 in w.g.) with the main burner operating on “high”.

To turn off the main burner :-

e)

Turn right hand control knob clockwise to the position marked

or press the down button on the remote handset until the flame

extinguishes, at this point a clicking noise will be heard from the motor.

To turn off the pilot flame :-

f)

Turn left hand control knob clockwise to the position marked

and the pilot flame will extinguish.

g)

After ensuring that the fire is safe to use it should be left on high

position to fully warm up. During this time a slight odour may be

noticed, this is due to the “newness” of the fire and will soon disappear.

Fig. 28

“Down” button to decrease

heat input or turn off main

burner

“Up” button to increase

heat input

22

Содержание KCFL**RN2 Series

Страница 1: ...ECORATIVE LOG EFFECT ROOM HEATER Installation and Maintenance Instructions Hand these instructions to the user Model No KCFL RN2 is for use on Natural Gas G20 at a supply pressure of 20 mbar in G B I...

Страница 2: ...gas connection checking for gas tightness 20 3 3 Lighting the appliance 21 23 3 4 Removal re fitting the trim 23 3 5 Checking for clearance of combustion products 24 Section 4 Maintenance 4 1 Removal...

Страница 3: ...ld Pressure G20 20 0 1 0 mbar 8 0 0 4 in w g Ignition Integral to gas valve Electrode Spark Gap 4 0mm Packed Weight Combustion Chamber 33 0 kg Fig 1 Top View of Combustion Side View of Combustion Cham...

Страница 4: ...nstalled in G B When Installing in I E please consult document I S 813 Domestic Gas Installation which is issued by the National Standards Authority of Ireland If installing in Northern Ireland please...

Страница 5: ...st however stand on a non combustible base that is a minimum thickness of 12mm 1 5 INSTALLATION TO PLASTERED WALL SURFACES If installing to a plastered wall all material must be removed from the 50mm...

Страница 6: ...mounting frame screws 1 off Loose Items pack containing 4 off No 12 x 40mm Screws 4 off Rawlplugs 4 off Adjustable screw in feet IMPORTANT NOTE BEFORE PROCEEDING WITH THE INSTALLATION This product req...

Страница 7: ...n Chamber Dimension A Minimum Width 750mm Maximum Width 780mm Dim A Dim B Dimension B Minimum Height 540mm Maximum Height 545mm Dim C Dimension C Minimum Depth 383mm Fig 3 Fig 4 A minimum clearance of...

Страница 8: ...rvicing purposes If installing without a flue liner please ensure that sufficient depth is available in the opening to collect a minimum volumetric area of 12 litres 0 012m3 of flue debris Refer to Fi...

Страница 9: ...ng with the installation of the fire an assessment of the area immediately above the fire is required see Fig 6 above If there is no existing openings within either triangle proceed with forming the o...

Страница 10: ...hown Fig 7 b The bottom section of the mounting frame can be removed from the main body of the mounting frame by removal of the four screws as indicated This may be required for servicing etc See fig...

Страница 11: ...ow Note Before breaking into the gas supply a gas tightness test should be carried out to establish that the existing pipework is sound 11 Combustion Chamber Gas Supply entering from L H S Combustion...

Страница 12: ...p brackets as shown below in Fig 13 These are clamped together to form the seal between the glass frame assembly and the combustion chamber Fig 13 NOTE Always ensure that a consistent seal between the...

Страница 13: ...flexible flue liner through the hole in the top of the combustion chamber The flexible liner should be then fitted to the 5 125mm spigot adaptor as shown below in Fig 14 Fig 14 b Re fit the 5 125mm f...

Страница 14: ...DRAUGHT DIVERTER IS FITTED IN THE CORRECT ORIENTATION IN THE COMBUSTION CHAMBER IT IS VERY IMPORTANT TO THE SAFETY AND PERFORMANCE OF THE PRODUCT THAT THE DRAUGHT DIVERTER IS RE FITTED DO NOT CONTINUE...

Страница 15: ...AUGHT DIVERTER HAS THE 3 OFF SCREWS FITTED AT THE FRONT EDGE NEAREST THE GLASS PANEL THIS WILL ENSURE THAT THE DRAUGHT DIVERTER IS FITTED IN THE CORRECT ORIENTATION IN THE COMBUSTION CHAMBER IT IS VER...

Страница 16: ...rear section as shown to allow the fitting of Log A Fig 19 b Place the largest Log A centrally onto the fuel bed support behind the burner flame strip Ensure that the fuel bed Log A is located centra...

Страница 17: ...ed base log A as shown below in Fig 21 using the groove in Log A as a guide for placement Fig 21 d Fit Log C into position on left hand side of the fuel bed base log A as shown below in Fig 22 using t...

Страница 18: ...base log A as shown below in Fig 23 using the groove in Log A as a guide for placement Fig 23 e Fit Log E into position at centre of the fuel bed base log A as shown below in Fig 24 using the groove i...

Страница 19: ...elow in Fig 26 using the raised section in the base log as a guide for position Fig 26 IMPORTANT NOTE HAVING FITTED THE GRAVEL MATERIAL IN THE BASE OF THE COMBUSTION CHAMBER ENSURE THAT NONE OF IT IS...

Страница 20: ...avy duty polythene bag clearly labelled as RCF waste This is not classified as hazardous waste and may be disposed of at a tipping site licensed for the disposal of industrial waste Protective clothin...

Страница 21: ...purged from the supply pipe Bring the knob back to its start position and turn it several times to the pilot position The pilot should light Hold in the control knob for at least 10 seconds to allow t...

Страница 22: ...ck that the gas pressure is 20 0 mbar 1 0mbar 8 0 in w g 0 4 in w g with the main burner operating on high To turn off the main burner e Turn right hand control knob clockwise to the position marked o...

Страница 23: ...NG OF THE TRIM ASSEMBLY a The aluminium trim is attached to the lid of the combustion chamber by hooking the retaining lip on the rear face of the trim assembly over the top of the combustion chamber...

Страница 24: ...e fire must be disconnected from the gas supply and expert advice obtained e If there is an extractor fan fitted any where in the vicinity of the appliance the spillage test should be repeated with th...

Страница 25: ...assembly from the fire 4 1 1 Isolate the gas supply 4 1 2 Remove trim from the front of the fire as shown in section 3 4 4 1 3 Remove the glass frame assembly from the fire as shown in section 2 6 4 1...

Страница 26: ...s to the bottom R H side of the control valve 4 4 Removing the Pilot Assembly 4 4 1 Isolate the gas supply 4 4 2 Remove trim from the front of the fire as shown in section 3 4 4 4 3 Remove the glass f...

Страница 27: ...over on the back of the handset Parts Shortlist Control Valve B 82290 ODS Pilot B 38930 Log Set Black Fibre Models B 83610 Glass Seal B 84180 Log Set Cream Fibre Models B 99020 Glass Panel B 81190 Rem...