background image

Warning : Use only the logs supplied with the fire. When replacing the

logs remove the old logs and discard them. Fit a complete set of logs of the

correct type. Do not fit additional logs or any logs other than a genuine

replacement set.

This appliance uses fuel effect pieces containing Refractory Ceramic Fibres (R.C.F.), which are

man-made vitreous silicate fibres. Excessive exposure to these materials may cause temporary

irritation to eyes, skin and respiratory tract. Consequently, it makes sense to take care when han-

dling these articles to ensure that the release of dust is kept to a minimum. To ensure that the

release of fibres from these R.C.F. articles is kept to a minimum, during installation & servicing we

recommend that you use a HEPA filtered vacuum to remove any dust and soot accumulated in and

around the fire, before and after working on the fire. When replacing these articles we recommend

that the replaced items are not broken up, but are sealed within a heavy duty polythene bag,

clearly labelled as “RCF waste”. This is not classified as “hazardous waste” and may be disposed

of at a tipping site licensed for the disposal of industrial waste. Protective clothing is not required

when handling these arrticles, but we do recommend you follow the normal hygiene rules of not

smoking, eating or drinking in the work area, and always wash your hands before eating or

drinking.

This appliance does not contain any component manufactured from

asbestos or asbestos related products.

Refit the glass frame as detailed in section 2.6 (page 12), then light the appliance as detailed in section

3.3

3.2

MAKING THE GAS CONNECTION & CHECKING FOR GAS

TIGHTNESS

a)

Before making the final gas connection, thoroughly purge the gas

supply pipework to remove all foreign matter, otherwise serious

damage may be caused to the gas control valve on the fire.

Failure to purge the gas supply will invalidate the guarantee.

b)

The gas connection should be made to the appliance inlet elbow to

using 8mm rigid tubing.

c)

Remove the pressure test point screw from the inlet elbow and fit a

manometer.

d)

Turn on the main gas supply and carry out a gas tightness test.

20

Содержание KCFL**RN2 Series

Страница 1: ...ECORATIVE LOG EFFECT ROOM HEATER Installation and Maintenance Instructions Hand these instructions to the user Model No KCFL RN2 is for use on Natural Gas G20 at a supply pressure of 20 mbar in G B I...

Страница 2: ...gas connection checking for gas tightness 20 3 3 Lighting the appliance 21 23 3 4 Removal re fitting the trim 23 3 5 Checking for clearance of combustion products 24 Section 4 Maintenance 4 1 Removal...

Страница 3: ...ld Pressure G20 20 0 1 0 mbar 8 0 0 4 in w g Ignition Integral to gas valve Electrode Spark Gap 4 0mm Packed Weight Combustion Chamber 33 0 kg Fig 1 Top View of Combustion Side View of Combustion Cham...

Страница 4: ...nstalled in G B When Installing in I E please consult document I S 813 Domestic Gas Installation which is issued by the National Standards Authority of Ireland If installing in Northern Ireland please...

Страница 5: ...st however stand on a non combustible base that is a minimum thickness of 12mm 1 5 INSTALLATION TO PLASTERED WALL SURFACES If installing to a plastered wall all material must be removed from the 50mm...

Страница 6: ...mounting frame screws 1 off Loose Items pack containing 4 off No 12 x 40mm Screws 4 off Rawlplugs 4 off Adjustable screw in feet IMPORTANT NOTE BEFORE PROCEEDING WITH THE INSTALLATION This product req...

Страница 7: ...n Chamber Dimension A Minimum Width 750mm Maximum Width 780mm Dim A Dim B Dimension B Minimum Height 540mm Maximum Height 545mm Dim C Dimension C Minimum Depth 383mm Fig 3 Fig 4 A minimum clearance of...

Страница 8: ...rvicing purposes If installing without a flue liner please ensure that sufficient depth is available in the opening to collect a minimum volumetric area of 12 litres 0 012m3 of flue debris Refer to Fi...

Страница 9: ...ng with the installation of the fire an assessment of the area immediately above the fire is required see Fig 6 above If there is no existing openings within either triangle proceed with forming the o...

Страница 10: ...hown Fig 7 b The bottom section of the mounting frame can be removed from the main body of the mounting frame by removal of the four screws as indicated This may be required for servicing etc See fig...

Страница 11: ...ow Note Before breaking into the gas supply a gas tightness test should be carried out to establish that the existing pipework is sound 11 Combustion Chamber Gas Supply entering from L H S Combustion...

Страница 12: ...p brackets as shown below in Fig 13 These are clamped together to form the seal between the glass frame assembly and the combustion chamber Fig 13 NOTE Always ensure that a consistent seal between the...

Страница 13: ...flexible flue liner through the hole in the top of the combustion chamber The flexible liner should be then fitted to the 5 125mm spigot adaptor as shown below in Fig 14 Fig 14 b Re fit the 5 125mm f...

Страница 14: ...DRAUGHT DIVERTER IS FITTED IN THE CORRECT ORIENTATION IN THE COMBUSTION CHAMBER IT IS VERY IMPORTANT TO THE SAFETY AND PERFORMANCE OF THE PRODUCT THAT THE DRAUGHT DIVERTER IS RE FITTED DO NOT CONTINUE...

Страница 15: ...AUGHT DIVERTER HAS THE 3 OFF SCREWS FITTED AT THE FRONT EDGE NEAREST THE GLASS PANEL THIS WILL ENSURE THAT THE DRAUGHT DIVERTER IS FITTED IN THE CORRECT ORIENTATION IN THE COMBUSTION CHAMBER IT IS VER...

Страница 16: ...rear section as shown to allow the fitting of Log A Fig 19 b Place the largest Log A centrally onto the fuel bed support behind the burner flame strip Ensure that the fuel bed Log A is located centra...

Страница 17: ...ed base log A as shown below in Fig 21 using the groove in Log A as a guide for placement Fig 21 d Fit Log C into position on left hand side of the fuel bed base log A as shown below in Fig 22 using t...

Страница 18: ...base log A as shown below in Fig 23 using the groove in Log A as a guide for placement Fig 23 e Fit Log E into position at centre of the fuel bed base log A as shown below in Fig 24 using the groove i...

Страница 19: ...elow in Fig 26 using the raised section in the base log as a guide for position Fig 26 IMPORTANT NOTE HAVING FITTED THE GRAVEL MATERIAL IN THE BASE OF THE COMBUSTION CHAMBER ENSURE THAT NONE OF IT IS...

Страница 20: ...avy duty polythene bag clearly labelled as RCF waste This is not classified as hazardous waste and may be disposed of at a tipping site licensed for the disposal of industrial waste Protective clothin...

Страница 21: ...purged from the supply pipe Bring the knob back to its start position and turn it several times to the pilot position The pilot should light Hold in the control knob for at least 10 seconds to allow t...

Страница 22: ...ck that the gas pressure is 20 0 mbar 1 0mbar 8 0 in w g 0 4 in w g with the main burner operating on high To turn off the main burner e Turn right hand control knob clockwise to the position marked o...

Страница 23: ...NG OF THE TRIM ASSEMBLY a The aluminium trim is attached to the lid of the combustion chamber by hooking the retaining lip on the rear face of the trim assembly over the top of the combustion chamber...

Страница 24: ...e fire must be disconnected from the gas supply and expert advice obtained e If there is an extractor fan fitted any where in the vicinity of the appliance the spillage test should be repeated with th...

Страница 25: ...assembly from the fire 4 1 1 Isolate the gas supply 4 1 2 Remove trim from the front of the fire as shown in section 3 4 4 1 3 Remove the glass frame assembly from the fire as shown in section 2 6 4 1...

Страница 26: ...s to the bottom R H side of the control valve 4 4 Removing the Pilot Assembly 4 4 1 Isolate the gas supply 4 4 2 Remove trim from the front of the fire as shown in section 3 4 4 4 3 Remove the glass f...

Страница 27: ...over on the back of the handset Parts Shortlist Control Valve B 82290 ODS Pilot B 38930 Log Set Black Fibre Models B 83610 Glass Seal B 84180 Log Set Cream Fibre Models B 99020 Glass Panel B 81190 Rem...

Отзывы: