background image

Feel the Future of Heating. Step out of the Shade and into the Sun

Infrared Heating

Instruction Manual: Glass & Mirror Infrared Heater

Summary of Contents for Infrared Heating

Page 1: ...Feel the Future of Heating Step out of the Shade and into the Sun Infrared Heating Instruction Manual Glass Mirror Infrared Heater ...

Page 2: ... when installing and using the appliance 4 Modification of the heater in any way voids the warranty 5 Make sure that the appliance is in good condition prior to installation and do not use the appliance if damaged 6 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities 7 Children shall not play with the appliance 8 Children of less...

Page 3: ...E Certified The Restriction of the Use of Certain Hazardous Substances RoHS in Electrical and Electronic Equipment Directive 2011 65 EU aims to prevent hazardous substances from entering the production process and thereby keep them out of the waste stream The Waste Electrical or Electronic Equipment WEEE Directive requires countries to maximise separate collection and environmentally friendly proce...

Page 4: ...ng The supply cord cannot be replaced If the cord is damaged the appliance should be scrapped The materials used for packaging is only to be used for transport and can be recycled Remove before use For disposal use dedicated recycling containers This appliance is intended for domestic use for room heating It must be fixed onto a wall as indicated in this instruction manual The means for disconnecti...

Page 5: ...in doubt ask professional qualified personnel The brackets on the Glass and Mirror heaters are suitable for wall mounting only The heater bracket provides the option of hanging your heater in either landscape or portrait orientation Rotate and fix to suit preferred position The wall bracket A is attached to the wall on 4 corners This must be done at a suitable height and position with the correct f...

Page 6: ...struction of wall Use a spirit level to ensure that the bracket is straight 3 Insert the grub screws into the wall bracket ensuring that the screw is only 2 3mm in to the bracket 4 The heater with bracket B attached to the heater can then be slid into the wall bracket A 5 Both retaining grub screws must be tightened to ensure that the heater is safely fixed to the wall C Use supplied 350mm screwdr...

Page 7: ... the grub screws Check the measurements between the brackets on the heater if there is still an issue with sitting the heater correctly These should match the measurements on the wall Two people must be used to install the 800w 1000w and 1500w heaters Ensure that the correct fixings have been used to fix the wall brackets to the wall Incorrect fixings could cause damage to the heater people or sur...

Page 8: ...earthed and connected to a supply that is earthed If the appliance is mounted in the bathroom or shower the power line must be equipped with an RCD with maximum rated current of 30mA In humid environments bathrooms kitchens laundry rooms etc it is very important that the electrical connection to the network is situated at least at 50 cm from the floor Your heater should not be operated without a co...

Page 9: ...chnical problems contact a qualified professional Do not attempt to repair it yourself Attempts to do so will invalidate your guarantee Disposal All ranges of our heaters are classed as electrical products and must not be disposed of in household waste The heater can be recycled Please contact your local council for advice on correct disposal This product carries a 5 year warranty from original dat...

Page 10: ... Setting these unused rooms at a base rate of 14 15º will allow the room to stay warm until they are required to be boosted to 19º This is perfect for bedrooms offices and spare rooms Sizing the Heaters Always follow the guidelines on our website for measuring the heat loss of your home A heater that is too small will not heat the room efficiently There is a potential to shorten the life of the he...

Page 11: ...www jigsawinfraredfactory com Phone 0121 794 2081 Solutions by Jigsaw LTD is a Limited Company registered in England and Wales Registered Office 1 St Kenelm Court Steel Park Lane Halesowen West Midlands B62 8HD Company Number 10669703 VAT 315 3643 21 1000w Printed Heater in Situ Infrared Heating ...

Reviews: