CONNECTION OF THE FLUE TERMINAL AND RE-FITTING THE
DRAUGHT DIVERTER.
a)
If fitting without a flue liner, into a chimney that is has had it’s
soundness assured by testing, and is less than 10 metres in
height on an external wall or 12 metres on an internal wall, then the
appliance can be fitted with the flue terminal as supplied. The
terminal is secured with 4 off M4 screws. See Fig. 17 below.
b)
Re-fit the draught diverter and secure with the five M4 screws as
shown below in Fig. 18, ensuring the edge with 3 screw location points
is at the front of the product.
Fig. 17
Fig. 18
15
IMPORTANT NOTE :
ENSURE THAT THE DRAUGHT DIVERTER HAS THE 3 OFF SCREWS
FITTED AT THE FRONT EDGE NEAREST THE GLASS PANEL. THIS WILL
ENSURE THAT THE DRAUGHT DIVERTER IS FITTED IN THE CORRECT
ORIENTATION IN THE COMBUSTION CHAMBER.
IT IS VERY IMPORTANT TO THE SAFETY AND PERFORMANCE
OF THE PRODUCT THAT THE DRAUGHT DIVERTER IS RE-FITTED.
DO NOT CONTINUE WITH THE COMMISSIONING OF THE PRODUCT
UNTIL THIS COMPONENT IS IN THE CORRECT POSITION.
ENSURE THE LABEL THAT SPECIFIES THE PRODUCT HAS BEEN
INSTALLED WITHOUT A FLUE LINER IS NOW CORRECTLY FILLED IN
WITH THE INSTALLERS DETAILS. THE LABEL IS FITTED TO THE GAS
INLET ELBOW AND MUST BE LEFT IN POSITION FOLLOWING
COMMISIONING OF THE PRODUCT.
Refit 5 off M4
Screws
Refit 4 off M4
Screws
NOTE : THE FLAT FACE OF THE
FLUE TERMINATION MUST BE
FITTED FACING TOWARDS THE
FRONT OF THE PRODUCT -
SEE FIG. 1 ON PAGE 3.