POWER PAK II / PLUS II
7
3. INTELLI-CHECK LED / Noise and Button Indicators
The POWER PAK II is fitted with INTELLI-CHECK Jumper Cables (14). Familiarize yourself with the features of the
INTELLI-CHECK as per below, prior to connecting to your vehicles battery.
Caution: Do Not press the “BOOST” Button (19) prior to connecting the jumper cables to your vehicle.
Note: Once the POWER PAK II is connected to your vehicles battery, the below indicators may be illuminated and function
buttons used when needed.
GREEN LED Illuminated (Correct Polarity LED) (20): Indicating that the jumper cable connections are correct and the circuit is
working and ready for use, you can turn the engine ignition key to jump-start the vehicle.
RED LED Illuminated (Reverse Polarity LED) (21) with buzzing: Indicating that the jumper cable connections are incorrect
(wrong) and buzzing to alarm the user to disconnect the battery clamps and re-correct the clamps correctly.
GREEN LED (Correct Polarity LED) (20) flashing with buzzing: Informing the user the vehicle battery is low, press the “BOOST
button (19), wait for the GREEN LED to illuminate then turn the engine ignition key within 30s.
NO LED’s Illuminated , No buzzing: Indicates the vehicle’s battery maybe damaged or the jumper cables may have a bad
connection to the vehicles battery terminals. Check the jumper cable connections to confirm a positive connection then, press
the “BOOST” Button (19), wait for the GREEN LED to illuminate.Then you can turn the engine ignition key to jump-start
the vehicle.
4. POWER PAK II Jump Starter Operation
WARNING! Do not leave your vehicle unattended at any time.
1. Press the ON/OFF/TEST Button (1) and ensure that the POWER PAK II Battery Charge LED Indicators (2) are illuminated
with a minimum of 3 BLUE LED’s.
2. Connect the BLUE connector plug located on the end of the INTELLI-CHECK Jumper Cable (14) into the
Jump Start Cable Port (9). Ensure that the BLUE connector plug is firmly pushed into the Jump Start Cable Port (9) for a
positive connection and ensure that the LED’s on the INTELLI-CHECK Jumper Cable (14) are NOT illuminated.
Note: Failing to securely locate the BLUE connector plug could result in a reduced electrical contact causing the plug
to melt or deform.
3. Connect the Jump Starter Battery Clamps (12 & 13) to the vehicles battery terminals correctly, connect the Positive
Battery Clamp RED (12) to the positive terminal (+ RED) of your vehicles battery and the Negative Battery Clamp BLACK
(13) to the negative terminal (- BLACK) of your vehicles battery.
4. Turn your ignition key to start the vehicle.
Note: If your vehicle does not start within 3 seconds wait for approx. 30 seconds and repeat steps 1-5.
5. When the vehicle has started, disconnect the POWER PAK II Jump Starter Battery Clamps (12 & 13) from the vehicle
battery within 30 seconds, starting with the Positive Battery Clamp RED (12) first and then the Negative Battery Clamp
BLACK (13).
6. After disconnecting the POWER PAK II Jumper Cables (12 & 13), leave the vehicle’s engine running to recharge
the battery.
20
19
21
14
(fig 3)
(fig 4)