1. Charging the POWER PAK II Battery (Cont.)

a.  240V AC Charger (10) - Once fully charged the 240V AC Charger (10) can be left connected to the POWER PAK II as the 

charger will perform a maintenance charge.

Caution: It is recommended that the 240V AC Charger (10) be turned OFF within 48 hours after charging has completed to  

save electricity.

b.  12V DC Car Charger (11) - It is not recommended to leave the POWER PAK II connected to your vehicles 12V output 

source for extended periods of time as this could potentially drain your vehicles battery.

Caution: If the POWER PAK II jump starter will not turn ON, the current overload or low voltage protection may have activated. 

To reset the jump starter you must connect the supplied 240V AC Charger (10) to your mains power, then connect the  
charger lead to the 15V DC 1A Input Charging Port (6) & turn ON the mains power. This will reset the POWER PAK II 
jump starter and should now function as normal.

POWER PAK II Operation

2. POWER PAK II Pre-Operation Check

Caution: Before using the POWER PAK II ensure your vehicle battery has a CCA rating of 400CCA or less for KP1405 & 600CCA 

or less for KP1406. 

Trying to start any vehicle with a battery rated greater than 400CCA for KP1405 & 600CCA for KP1406 could trip the 
current overload protection or cause damage to the POWER PAK II and void the product warranty. 
Caution: Refer to your vehicles instruction manual for “connection of jumper cables” as some vehicles have specific  

connection requirements.

3.  Follow the below instructions when your vehicle will not start due to a low voltage, flat, damaged or low  

temperature battery.

4.  Ensure the Battery Charge LED Indicators (2) are illuminated, a minimum of 3 BLUE LED’s are illuminated before trying 

to jumpstart your vehicle. 

5.  Do not attempt to jumpstart your vehicle if the Battery Charge LED Indicators (2) are illuminated with less than  

3 BLUE LED’s.

6.  If the Battery Charge LED Indicators (2) are showing 2 or less illuminated BLUE LED’s; recharge the POWER PAK II as 

specified in “Charging the POWER PAK II Battery” on Pages 5 & 6.

7.  Do not touch or connect the Positive Battery Clamp RED (12) to the Negative Battery Clamp BLACK (13)  

at any stage. Connecting the Battery Clamps (12 & 13) together may lead to damage of the POWER PAK II, and/or 
vehicles battery and could be dangerous.

8.  Always ensure you connect the jump starter clamps to the correct battery terminals, connect the Positive Battery 

Clamp RED (12) to the positive terminal (+ RED) of your vehicles battery and the Negative Battery Clamp BLACK (13) to 
the negative terminal (- BLACK) of your vehicles battery otherwise you may cause damage to the POWER PAK II  
or your vehicle.

9.  Always check that the Battery Clamps (12 & 13) have a good connection to the vehicle battery terminals.
10.  Check that the vehicle battery terminals are free of corrosion and are clean, to ensure a positive connection of the 

POWER PAK II.

11.  Do not try to restart the vehicle after 3 consecutive starting attempts, otherwise you may cause damage to the  

POWER PAK II. Check your vehicle for other possible reasons prior to trying to start your vehicle again.

Содержание KP1405

Страница 1: ...POWER PAK II PLUS II MULTI FUNCTION JUMP STARTERS KP1405 KP1406 ED2 December 17 ...

Страница 2: ...rs 16 Multi Purpose Accessory Cable 17 Electronic Device Charging Cable 18 12V DC Female Adaptor 19 BOOST Button 20 Correct Polarity LED 21 Reverse Polarity LED INTELLI CHECK Jumper Cable Reverse Polarity Check Anti recharge Protection Short Circuit Protection Over Discharge Protection Surge Protection 10 Specifications KP1405 POWER PAK II KP1406 POWER PAK PLUS II Size 176 x 93 x 38mm 227 x 93 x 3...

Страница 3: ...coins keys nails screws or other small metal objects that can make a connection from one terminal to another Shorting the battery terminals together may cause burns or a fire 9 This appliance is not intended for use by persons including children with reduced physical sensors or mental capabilities or lack of experience and knowledge unless they have been given supervision or instructions concernin...

Страница 4: ...charger is double insulated therefore no earth wire is required Always check that the mains voltage corresponds to the voltage on the rating plate Never attempt to replace the charger unit with a regular mains plug The Charger is intended for indoor use only Dispose of battery as per local government requirements Read the instruction manual before use Risk of explosion Warning Energy efficiency ra...

Страница 5: ...uminated LED s Battery Charge Condition 0 10 25 50 75 100 A Charging with the 240V AC Charger a To charge the POWER PAK II with the 240V AC Charger 10 locate the charger plug adaptor on the end of the charging cable of the 240V AC Charger 10 and insert into the POWER PAK II 15V DC 1A input Charging Port 6 fig1 b Plug the 240V AC Charger 10 into your wall socket and turn ON the mains power When the...

Страница 6: ...s have specific connection requirements 3 Follow the below instructions when your vehicle will not start due to a low voltage flat damaged or low temperature battery 4 Ensure the Battery Charge LED Indicators 2 are illuminated a minimum of 3 BLUE LED s are illuminated before trying to jumpstart your vehicle 5 Do not attempt to jumpstart your vehicle if the Battery Charge LED Indicators 2 are illum...

Страница 7: ...r the GREEN LED to illuminate Then you can turn the engine ignition key to jump start the vehicle 4 POWER PAK II Jump Starter Operation WARNING Do not leave your vehicle unattended at any time 1 Press the ON OFF TEST Button 1 and ensure that the POWER PAK II Battery Charge LED Indicators 2 are illuminated with a minimum of 3 BLUE LED s 2 Connect the BLUE connector plug located on the end of the IN...

Страница 8: ...cuit Tripping the over current protection circuit will turn OFF the POWER PAK II temporarily 1 Connect the Multi Purpose Accessory Cable 16 into the 19V DC 3 5A Output Port 4 2 Choose the correct Laptop Charger Adaptor 15 from the choice of 8 available adaptors provided with your POWER PAK II kit and plug the adaptor onto the end of the Multi Purpose Accessory Cable 16 3 Connect your chosen chargi...

Страница 9: ...I Please note that the POWER PAK II is only meant to operate small low amperage accessories not items such as in vehicle refrigerators winches etc 8 LED Torch Emergency Light 1 Press and hold the ON OFF TEST button 1 for approx 3 seconds to turn ON the LED Torch Emergency Light 5 2 To change to the STROBE LED mode press the ON OFF TEST Button 1 once 3 To change to the SOS LED mode press the ON OFF...

Страница 10: ...ged sitting in my vehicle A The POWER PAK II can remain up to 80 charge for up to 6 8 months The internal temperature of your vehicle can affect the battery charge time so it is recommended to check or recharge the POWER PAK II every 3 6 months to ensure it is in optimal working condition 10 Resetting The Current Overload To reset the current overload feature you need to connect the 240V AC Charge...

Страница 11: ...a Pty Ltd of 3 Lakeview Drive Caribbean Park Scoresby Victoria Tel 1300 657 528 The applicable warranty period 12 months commences on the date that the product is purchased If this product has materials or workmanship defects other than defects caused by abnormal or non warranted use you can at your cost send the product to place of purchase an authorised Kincrome service agent or one of Kincromes...

Страница 12: ...1 2 www kincrome com au ...

Отзывы: