![Kinco CD420 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/kinco/cd420/cd420_user-manual_1967678023.webp)
23
Chapter 5 Trial Operation & Parameter Introduction
5.1 Trial Operation
5.1.1 Objective
The trial operation allows you to test whether the driver works properly, and whether the motor runs stably.
5.1.2 Precautions
1. Ensure that the motor is running without load. If the motor flange is fixed on the machine, ensure that the
motor shaft is disconnected from the machine.
2. Ensure that motor cables, motor encoder cables, and power circuits (power lines and control power lines)
are properly connected. For details, see Chapter 3.
3.
During the trial operation, if you long press ▲ or ▼ when the motor is running, pulse signals, digital input
signals, and analog signals of the external controller are temporarily unavailable, so safety must be ensured.
4. During the trial operation, the system automatically adopts the instantaneous speed mode, that
is, the ―-3‖
mode.
5. After the trial operation, Group F006 exits automatically. To enter Group F006 again, you must re-activate the
trial operation.
6. If motor/encoder cables are wrongly connected, the actual rotation speed of the motor may be the possible
maximum rotation speed, or the rotation speed is 0 and the actual current value is the maximum value. In
this case, make sure to release the button; then check cable connection and test it again.
5.1.3 Operating Steps
1. Press
MODE
to enter Group F004. Select t
he object address ―d4.18‖, and check the motor type.
2. Press
MODE
to enter Group F000. Select the object address ―d0.02‖, and set the target speed to
―SpeedDemand_RPM".
3. Press
MODE
to enter Group F006. Arrange a test for keys, with the default value of d6.40.
Firstly, press ▼ to
adjust the data to d6.31. Then, press ▼, the data automatically changes to ―d6.15‖. Finally, press ▲ to adjust
the data to d6.25.
4. Press
ENTER
to activate trial operation. In this case, the numeric display is ―adc.d‖, and the motor shaft
releases. When long pressing ▲ or ▼, the motor automatically locks, and runs according to
―+SpeedDemand_RPM‖ or ―-SpeedDemand_RPM‖ separately. During the trial operation, the numeric
displays the motor speed in real time.
Содержание CD420
Страница 8: ...8 1 3 3 Power Brake and Encoder cable of Motors...
Страница 16: ...16 3 4 Power Interfaces CD420 X2 CD430 CD620 X2 and X5 of CD Driver Fig 3 4 Power interfaces of a CD driver...
Страница 22: ...22 Fig 4 3 Separate regulation of bits...
Страница 78: ...78...
Страница 99: ...99 Chapter 11 Specification 11 1 Servo Drivers and Motors Selection Table...
Страница 100: ...100 11 2 Servo Driver 11 2 1 Technical Specification Table for Servo Driver...
Страница 101: ...101 11 2 2 Mechanical Dimension Diagram for Servo Driver...
Страница 102: ...102 11 3 Dimensions Torque Curve Technical Specifications of Servo Motors 11 3 1 SMH60 Servo Motor...
Страница 103: ...103 11 3 2 SMH80 Servo Motor...
Страница 104: ...104 11 3 3 SMH110 Servo Motor 1 Technical Specification Table...
Страница 105: ...105 2 Dimension Torque Curve...
Страница 106: ...106 11 4 Wiring Diagram for Servo Motor Cable 11 4 1 Wiring Diagram for the Power Cable...
Страница 107: ...107 11 4 2 Wiring Diagram for the Encoder Cable...