Connections
WARNING:
Do not install or tighten any fittings,
gauges, or any other connections while there is pressure
on the line.
Remove plastic plugs from 1/4” NPT openings. Use 1/4”
or 3/8” tubing (not provided).
Throttle Mode:
Connect supply gas filter and pressure
gauge to any of the three ports labeled “T” and plug the
remaining “T” port. Connect supply line to filter. Use “S”
ports for Vent.
Snap Mode:
Connect supply gas filter and pressure
gauge to any of the three ports labeled “S” and plug the
remaining “S” port. Connect supply line to filter. Use “T”
ports for Vent.
Supply for
Snap Mode
Supply for
Throttle Mode
Installation
Vent:
Connect a Vent Line or Breather Plug to one of the
three Vent ports, and install plugs in remaining two ports.
Output
: Connect pressure gauge to either port labeled
“OUT”, where it is easiest for operator to see. Connect
output line to remaining “OUT” port.
CAUTION:
Ensure supply gas is clean and dry.
Vent for
Snap Mode
Vent for
Throttle Mode
Output
Snap and Throttle Mode Switch
To switch from one mode to the other, swap all “T”
(Throttle - top row) port connections with “S” (Snap -
bottom row) port connections (including supply gas filter)
and move Pilot Lever from one side to the other. See
Pilot Lever Location table below.