Maintenance - Pilot Assembly

Pilot - Disassembly

Step 1 – Remove 3 socket screws (1/8" hex key) holding 

pilot to enclosure. Remove pilot by prying under flats and 

then pulling pilot out.

Step 2 – Remove and discard 4 O-rings around outside 

of pilot cartridge.

Step 3 – Place flats on lower pilot cartridge into vise or 

hold in place with wrench.

Step 4– Unthread and carefully remove flanged top pilot 

cap to (3/8" socket).

Step 5 – Carefully remove upper diaphragm assembly to 

avoid damaging conical spring. If diaphragm is stuck, do 

not pry with screwdriver. Use pliers to pull out diaphragm 

assembly.

To remove pilot plug, turn pilot assembly over and it 

will fall out. Inspect pilot plug and seat surfaces shown 

for scratches, pitting, or any other potential leak paths. 

Clean off any debris.

Step 6 – Holding flats of pilot cartridge in place, unthread 

and remove bottom pilot cap (3/8" socket).

Step 7 - Remove lower diaphragm assembly and lower 

spring. If diaphragm is stuck, do not pry with screwdriver. 

Use pliers on stem of actuator to pull out diaphragm 

assembly.

Step 8 - Clean out all communication holes.

Pilot - Reassembly

Step 1 – Clean pilot cartridge and install pilot plug, small 

diameter first, into the side of the cartridge with the upper 

seat.

Step 2 – Place conical spring on upper diaphragm 

assembly. Apply grease to assembly where spring rests.

Step 3 – Place booster spring in top cap. Apply grease in 

top cap where spring sets.

Step 4 – Place diaphragm assembly in pilot block such 

that conical spring contacts pilot plug.

Step 5 – Screw the top cap (3/8" socket) into the pilot 

cartridge. Ensure that spring is centered on the upper 

diaphragm assembly. Torque top cap to 25-30 in·lbs.

Step 6 – Place lower spring on lower diaphragm 

assembly and install into lower portion of pilot cartridge.

Step 7 – Install lower cap (3/8" socket) over lower 

diaphragm assembly. Torque lower cap to 25-30 in·lbs.

Step 8 – Install 4 new O-rings into grooves on outside of 

cartridge. Apply grease to O-rings.

CAUTION:

 Do not allow grease to get on any other 

components or into communication holes.  If grease gets 

into pilot plug/seats, or blocks communication paths, the 

pilot might not operate correctly.

Step 9 – Insert pilot cartridge into enclosure.

Step 10 – Install 3 socket screws (1/8" hex key) to retain 

pilot.

Содержание GEN 3

Страница 1: ...PNEUMATIC LEVEL CONTROLLER GEN 3...

Страница 2: ...ade to ensure their accuracy they are not to be construed as warranties for guarantees express or implied regarding Kimray products or services described herein or their use or ap plication All sales...

Страница 3: ...ct Switch 5 Left hand right hand conversion 5 INSTALLATION Install Onto Vessel 6 Connections 7 Snap and throttle mode switch 7 OPERATION Start up 8 Calibration 8 Span adjustment 8 MAINTENANCE Paraffin...

Страница 4: ...ance information for the product A2 Description The Gen 3 Liquid Level Controller is designed for use in single phase interface liquid control applications The pilot is capable of both Snap mode on of...

Страница 5: ...orque Lever Cap Screw Set Screw 1 2 NPT Plug Cap Screw Spring Adjustment Assembly Mount A B C D C E F G Mount Orientation The Gen 3 can be ordered in either Left Hand or Right Hand mount but if you ne...

Страница 6: ...leed valve Make sure all pressure is released from vessel and confirm no pressure remains in supply gas instrument air lines Do not install in a location where Max Allowable Working Pressure could be...

Страница 7: ...labeled S and plug the remaining S port Connect supply line to filter Use T ports for Vent Supply for Snap Mode Supply for Throttle Mode Installation Vent Connect a Vent Line or Breather Plug to one o...

Страница 8: ...uced Operation Snap Mode Direct Acting Fail Closed aka PO valve With the output at 0 psi turn the set point adjustment knob counterclockwise to snap on producing the full output pressure Then turn the...

Страница 9: ...be replaced use the Technical Specs document 08 05 1 to determine which part number s are needed and contact your local Kimray authorized store or distributor to order WARNING A leaking controller is...

Страница 10: ...Use pliers on stem of actuator to pull out diaphragm assembly Step 8 Clean out all communication holes Pilot Reassembly Step 1 Clean pilot cartridge and install pilot plug small diameter first into t...

Страница 11: ...e 11 www kimray com Maintenance Pilot Assembly Pilot Pilot Screw Top Cartridge Cap Upper Diaphragm Assy Booster Spring Pilot Plug O Ring Bottom Cap O Ring O Ring O Ring Booster Pilot Spring Lower Diap...

Страница 12: ...m hubs Inspect flanged bearings for wear or damage Remove and discard O rings and back up rings inside hubs Step 9 Inspect shaft for wear or damage Clean out inside of mount Mount Reassembly Step 1 In...

Страница 13: ...peration Maintenance Guide 13 www kimray com Maintenance Mount Assembly Back Up Bearing Hub Flanged Bearing Torque Lever Socket Plug Displacer Arm O Ring Gasket Torque Shaft Mount O Ring O Ring Back U...

Страница 14: ...and remove from enclosure Step 4 Remove spring adjusting knob from bushing Remove and replace PTFE washer and O ring on spring adjusting knob Spring Assembly Reassembly Step 1 Install spring adjustin...

Страница 15: ...hutoff supply pressure to controller and bleed supply line Step 2 Remove the supply line from the filter and remove the filter from the controller Step 3 Clean out filter element Using compressed air...

Страница 16: ...ressure from pilot Inspect pilot O rings and diaphragms Replace if necessary 5 Displacer rod not able to move full range Solids or other obstruction inside of vessel restricting movement of displacer...

Страница 17: ...PNEUMATIC LEVEL CONTROLLER MODEL GEN 3 Installation Operation Maintenance Guide 17 www kimray com Page left blank...

Страница 18: ...PNEUMATIC LEVEL CONTROLLER MODEL GEN 3 Installation Operation Maintenance Guide www kimray com 18 Page left blank...

Страница 19: ...vere service control valve Please visit our website for up to date product data www Kimray com PNEUMATIC LEVEL CONTROLLER MODEL GEN 3 Installation Operation Maintenance Guide For questions or comments...

Страница 20: ...2018 Kimray Inc RM 0021 Issued 3 21 Kimray com...

Отзывы: