14
13. OPERATING YOUR ALARM
Feature
Audible
LED
Comment
Smoke alarming
3 repeated long beeps
3 flashes, synchronised with
audible alarm
Follow appropriate emergency
procedures
CO alarming
4 repeated shorter beeps
4 flashes, synchronised with
audible alarm
Test mode
3 long beeps repeated twice,
followed by 4 short beeps
repeated twice
Flashes synchronised with audible
beeps
Low Battery
Chirp every 60 seconds
Flashes every 30 seconds
Replace unit (sealed-in battery cannot be
replaced)
Smoke or CO Hush
None
Flashes every 10 seconds
Lasts for 10 minutes
Cancel Hush mode
NA
NA
Within the 10 minutes, the user can
cancel Hush by re-pressing Hush button
Normal operation
None
Flashes every 10 minutes
For 10 minutes after initial power-up,
the LED flashes every 60 seconds,
followed by the flash every 10 minutes.
Fault Mode
Chirp every 30 secs
Fault code (2 - 12 flashes every 30
seconds)
Call consumer hotline;
UK (0800 917 0722)
Ireland (1 800 818 601)
End of Life*
2 chirps every 30 seconds
2 flashes every 30 seconds
Replace unit after deactivation. Use End
of Life Hush temporarily*
* End of Life hush feature – Silences End of Life chirps for 3 days. Can be used 10 .mes within 30 days.
2534-7208-00(WFPCO)_UK_V14.qxp:_ 2015.12.3 2:58 PM Page 14