12. KEY FEATURES OF YOUR ALARM

This is a combina0on alarm, and is designed to detect dangerous levels of smoke and carbon

monoxide.

This alarm gives an audible (85 decibel alarm) warning as well as visual LED no0fica0on

when dangerous levels of either smoke or CO are detected, but where both are detected

simultaneously, priority is given to the smoke warning.

This alarm has an end-of-life signal, designed to alert you when the alarm sensor is no longer

opera0onal (a"er 10-years).
This alarm has a ‘Hush’ feature which allows nuisance alarms to be temporarily silenced.

2534-7208-00(WFPCO)_UK_V14.qxp:_  2015.12.3  2:58 PM  Page 13

Содержание WFPCO

Страница 1: ...43 CPR 0268 15 EN14604 2005 10 year Smoke CO Combina0on Alarm User Guide Sealed in ba1ery that lasts the life of the alarm WFPCO EN50291 1 2010 2534 7208 00 WFPCO _UK_V14 qxp _ 2015 12 3 2 58 PM Page...

Страница 2: ...arbon Monoxide Safety Informa0on 8 Recommended loca0ons for this alarm 9 Where not to install this alarm 10 INSTALLATION INSTRUCTIONS 11 Ac0va0ng the alarm 12 Key features of your alarm 13 Opera0ng yo...

Страница 3: ...ngs on back of the unit Your alarm was designed to detect both smoke and carbon monoxide from any source of combus0on in a residen0al environment It is not tested for use in a caravan or boat This app...

Страница 4: ...Alert small children DO Exit the home according to your escape plan DO Crawl if the smoke is dense using a damp cloth to breathe through DO Call the re brigade from a neighbour s home DO Ensure that e...

Страница 5: ...impaired by the use of drugs or alcohol In this case an alarm should be 1ed in each sleeping area Smoke alarms can save lives but they are not an alterna0ve for an adequate insurance policy to protect...

Страница 6: ...o detect CO gas It is not designed to detect other gases such as natural gas NOTE This alarm is intended for use in ordinary family homes It is not designed to measure compliance with occupa onal safe...

Страница 7: ...rm con nues to sound even a er being reset where appropriate then evacuate the premises aler ng other occupants to the risk Leave doors and windows open Do not re enter the premises 3 Get medical help...

Страница 8: ...the CO may have dispersed before help arrives It is crucial that the source of CO is determined and appropriate maintenance carried out Carbon monoxide is a cumula0ve poison This alarm is 0me weighted...

Страница 9: ...alarm in less than 3 minutes Parts per Million PPM E ects on Adults 100 Slight headache nausea fa0gue u like symptoms 200 Dizziness and headache within 2 3 hours 400 Nausea frontal headache drowsiness...

Страница 10: ...to 3 metres from the appliance If installing in the kitchen locate 1 to 3 metres away from direct cooking areas CO alarms in rooms with sloped ceilings should be located on the high side of the room...

Страница 11: ...or fans air vents or other similar ven la on openings Within 1 metre of a uorescent light Bathrooms or within 1 metre of the bathroom or sinks This alarm is intended for domes c use only it is not tes...

Страница 12: ...l it is snug against surface DO NOT over tighten OPTION 2 Mounting onto other Surfaces 1 Choose a location wall or ceiling and using the mounting plate provided as a template mark three hole locations...

Страница 13: ...0ghten If the unit needs to be re aligned rotate the alarm an0 clockwise remove and rotate to the desired alignment NOTE This alarm will mount to the plate in 3 posi0ons every 120 degrees The alarm b...

Страница 14: ...ca0on when dangerous levels of either smoke or CO are detected but where both are detected simultaneously priority is given to the smoke warning This alarm has an end of life signal designed to alert...

Страница 15: ...every 10 seconds Lasts for 10 minutes Cancel Hush mode NA NA Within the 10 minutes the user can cancel Hush by re pressing Hush button Normal operation None Flashes every 10 minutes For 10 minutes aft...

Страница 16: ...0 seconds Alarm needs to be replaced Alarm Fault Chirp every 30 secs Fault code 2 12 flashes every 30 seconds Call consumer hotline UK 0800 917 0722 Ireland 1 800 818 601 End of Life 2 chirps every 30...

Страница 17: ...o 90 RH non condensing Storage and Transport Condi0ons 20 C to 65 C 5 95 RH non condensing Alarm Sound 85dB 3m a er 1 min 82dB a er 4 min Dimensions Diameter 5 25 133 3mm Height 1 6 40 3mm Weight Weig...

Страница 18: ...Failure to turn o alarm as instructed prior to disposal may create poten0al for lithium ba1ery related re or hazard Break through label with a screw driver Turn the screw to the OFF location This will...

Страница 19: ...ora0ng or using adhesives close to the alarm remove it temporarily Keep away nappy buckets Storage and Transport Condi0ons 20 C to 60 C 5 95 RH non condensing The following substances can a ect the se...

Страница 20: ...ed abused or altered a er the date of purchase or if it fails to operate due to improper maintenance THE LIABILITY OF KSE LTD OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS ARISING FROM THE SALE OF T...

Страница 21: ...ease recycle where facili0es exist Check with Local Authority or retailer for recycling advice Kidde Helpline UK 0800 917 0722 Ireland 1 800 818 601 For CO Emergencies Gas Emergency Services 0800 111...

Страница 22: ...tional reliability vibration resistance Durability of operational reliability humidity resistance Durability of operational reliability corrosion resistance Durability of operational reliability elect...

Страница 23: ...Hotline at 0800 917 0722 or contact us at our website at www kiddesafetyeurope co uk Kidde Safety Europe Limited Mathisen Way Poyle Road Colnbrook Berkshire SL3 0HB Made in China P N 2534 7208 00 2534...

Отзывы: