When installing the battery, press the battery reminder finger 
down into the battery compartment and install the battery (see 
Figure 9).

CAUTION! IF THE BATTERY REMINDER FINGER IS NOT HELD 
DOWN IN THE BATTERY COMPARTMENT BY THE BATTERY, 
THE BATTERY DOOR WILL NOT CLOSE, THE A.C. QUICK 
CONNECTOR WILL NOT ATTACH TO THE ALARM, AND THE 
ALARM WILL NOT ATTACH TO THE TRIM RING.

The Model P12040 Smoke Alarm uses a 9V backup battery 
(Carbon zinc, alkaline and lithium batteries may be used). A fresh 
battery should last for one year under normal operating condi-
tions.  This alarm has a low battery monitor circuit which will 
cause the alarm to “chirp” approximately every 30 - 40 seconds 
for a minimum of seven (7) days when the battery gets low.  
Replace the battery when this condition occurs.

USE ONLY THE FOLLOWING 9 VOLT BATTERIES FOR SMOKE 
ALARM REPLACEMENT.

Carbon Zinc Type: 

EVEREADY 1222;

 

 

GOLD PEAK 1604P OR 1604S

Alkaline Type: 

ENERGIZER 522; DURACELL MN1604,      

  MX1604,GOLD 

PEAK 

1604A 

 

 

PANASONIC 6AM6, 6AM-6, 6AM-6PI, 

  6AM6X, 

and 

6LR61(GA)

Lithium Type: 

ULTRALIFE U9VL-J

NOTE: WEEKLY TESTING IS REQUIRED.

WARNING!! USE ONLY THE BATTERIES SPECIFIED.  USE OF 
DIFFERENT BATTERIES MAY HAVE A DETRIMENTAL EFFECT 
ON THE SMOKE ALARM.

CLEANING YOUR ALARM

YOUR ALARM SHOULD BE CLEANED AT LEAST ONCE A YEAR

To clean your alarm, remove it from the mounting bracket as out-
lined in the beginning of this section.  You can clean the interior 
of your alarm (sensing chamber) by using compressed air or a vac-
uum cleaner hose and blowing or vacuuming through the open-
ings around the perimeter of the alarm.  The outside of the alarm 
can be wiped with a damp cloth. If cleaning does not restore the 
alarm to normal operation the alarm should be replaced.

After cleaning, reinstall your alarm. Test your alarm by using the 
test button and check that the green LED is on.

1375-7213-00(21008164-EN A).indd   11

1375-7213-00(21008164-EN A).indd   11

2010.10.7   2:06:25 PM

2010.10.7   2:06:25 PM

Содержание P12040

Страница 1: ...u expect nothing less when the lives of your family are at stake Kidde alarms and accessories CAN ONLY BE interconnected with other Kidde alarms and accessories as well as specified brands and models...

Страница 2: ...thest from the exit If more than one sleeping area exists locate addi tional alarms in each sleeping area Locate additional alarms to monitor any stairway as stairways act like chimneys for smoke and...

Страница 3: ...d peaked or cathedral ceilings at or within 3 ft 0 9m of the highest point measured hori zontally NFPA 72 states Smoke alarms in rooms with ceiling slopes greater than 1 ft in 8 ft 3m in 2 4m horizont...

Страница 4: ...USE 2 LOCATIONS TO AVOID In the garage Products of combustion are present when you start your automobile Less than 4 10cm from the peak of an A frame type ceiling In an area where the temperature may...

Страница 5: ...nverters These types of inverters are sometimes used to supply power to the structure in off grid installations such as solar or wind derived power sources These power sources produce high peak voltag...

Страница 6: ...ndard UL listed household wire as required by local codes available at all electrical supply stores and most hardware stores FIGURE 4 INTERCONNECT WIRING DIAGRAM WIRES ON ALARM HARNESS CONNECTED TO Bl...

Страница 7: ...e that the mounting screws are positioned in the small ends of the keyholes before tightening the screws see figure 5 5 Plug the AC QUICK CONNECTOR into the back of the alarm see figure 6 making sure...

Страница 8: ...H CONTROL The HUSH feature has the capability of temporarily desensitizing the alarm circuit for approximately 10 minutes This feature is to be used only when a known alarm condition such as smoke fro...

Страница 9: ...m which senses the smoke or is being tested the originating unit will flash rapidly All other units in the interconnect system will sound an alarm but their red LED s will NOT flash rapidly The green...

Страница 10: ...sance alarms For more information refer to section 4 OPERATION AND TESTING 6 MAINTENANCE IF TAMPER RESIST PIN HAS BEEN USED REFER TO TAMPER RESIST LOCKING PIN IN SECTION 3 FOR PIN REMOVAL INSTRUCTIONS...

Страница 11: ...ADY 1222 GOLD PEAK 1604P OR 1604S Alkaline Type ENERGIZER 522 DURACELL MN1604 MX1604 GOLD PEAK 1604A PANASONIC 6AM6 6AM 6 6AM 6PI 6AM6X and 6LR61 GA Lithium Type ULTRALIFE U9VL J NOTE WEEKLY TESTING I...

Страница 12: ...are often unpredictable For maximum protection Kidde recom mends that both Ionization and Photoelectric alarms be installed A battery powered alarm must have a battery of the specified type in good c...

Страница 13: ...l occupants to test your plan before an emergency You may not be able to reach your chil dren It is important they know what to do Current studies have shown smoke alarms may not awaken all sleeping i...

Страница 14: ...in existing one and two family dwelling units 2 Outside of each separate sleeping area in immediate vicinity of the sleeping rooms 3 On each level of the dwelling unit includ ing basements Exception I...

Страница 15: ...smoke alarm installed in each separate sleeping area in the vicinity of but outside of the bedrooms and heat or smoke alarms in the living rooms dining rooms bedrooms kitch ens hallways attics furnace...

Страница 16: ...ANY CASE EXCEED THE COST OF REPLACEMENT OF SMOKE ALARM AND IN NO CASE SHALL KIDDE OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS BE LIABLE FOR CONSEQUENTIAL LOSS OR DAMAGES RESULTING FROM THE FAILUR...

Отзывы: