Accessories

 Rack mount kit without handles  

  (Option 1CM) 

  Adds a rack mount (5063-9217) and rail kit (E3663AC) for use  
  without handles.

 

Rack mount kit with handles (Option 1CP) 

  Adds a rack mount (5063-9237)

1

 and rail kit (E3663AC) for use  

  with standard supplied handles.

Configuration Details

Selecting the correct mixer-test 
configuration:

Most mixer or converter test applications require Options 014, 080, 
and 082 for conversion loss/gain, or Options 014, 080, 081 and 083 
for conversion loss/gain and phase/delay measurements. If you want 
to create and automate your own custom frequency-offset measure-
ments (for example, intermodulation distortion), 
you may only need Options 014 and 080. For converters that require 
input power below -27 dBm, or for devices that have a large amount 
of LO feedthrough (like an unfiltered mixer), Option UNL, which adds 
source attenuators, is highly recommended. Besides allowing lower 
input power levels, these attenuators improve the isolation between 
the PNA’s internal source and 
LO leakage signals, helping to prevent source-unleveled errors. For 
devices that put out signals near or above the receiver’s compression 
levels (which varies between –3 and +5 dBm, depending on the 
model and frequency), Option 016 is recommended, which adds 
receiver attenuators. Finally, Option 010, which adds time-domain 
analysis, is very useful for gating out unwanted, time-delayed 
responses which often occur when measuring mixers. 

 

4-port measurement application  

  (Option 550)

 Adds multiport analyzer mode to any PNA network analyzer    
with Option 014 configurable test set, which enables full    
4-port error correction and measurement capabilities using an  
 external test set. Only standard measurement class is available  
 in the multiport analyzer mode.

 

N-port capabilities (Option 551)

 Adds multiport analyzer mode to any PNA network analyzer  
 with Option 014 configurable test set, which enables full    
N-port error correction and measurement capabilities using  
 an external test set. Only standard measurement class is    
available in the multiport analyzer mode.

Pulse, antenna, mm-wave

 

Pulsed-RF measurement capability  

  (Option H08)

 

Provides software to set up and control pulsed-RF measurements  

 with point-in-pulse capability. The software sets the coefficient  
 of the PNA’s digital-IF filter to null out unwanted spectral 
 components, enables the IF gates provided with IF access    
(Option H11), and controls selected Keysight pulse generators.  
 It can be run on the PNA or an external computer. A “.dll” file   
containing the IF-filter algorithms is included for automated    
pulsed-RF testing. The pulsed application is configured to work  
 with the Keysight 81110A series pulse generator. 
 For more detailed information regarding pulsed measurement  
 capabilities with the microwave PNA refer to the Keysight  

 

Web site 

www.keysight.com/find/pna

 and download the PNA    

Series MW Network Analyzers Configuration Guide for Pulsed  
 Measurements, literature number 5989-7913EN. 

 

IF access (Option H11)

 

 Provides hardware to enable antenna, point-in pulse, and   
broadband millimeter-wave measurements to 110 GHz. For  
 each of the MW PNA’s measurement receivers, IF gates    
(enabled with pulsed measurement capability, Option H08) and  
 external IF inputs are added. In addition, access to the PNA’s   
internal RF and LO source is provided for remote mixing 
 applications. For basic antenna measurements, only Option H11  
 is necessary. Pulsed antenna applications also require the    
pulsed measurement capability (Option H08). Broadband  

 

 measurements to 110 GHz, also requires an N5260A  

 

 millimeter-wave test set controller. 
 Note: Use external IF access for up to 20 dB more sensitivity   

when making antenna measurements with a remote mixing    

configuration. Add Option H08 (Pulsed-RF Measurement    

 Capability) to enable advanced pulsed measurements. Or    

upgrade to a broadband (10 MHz to 110 GHz) VNA system    

simply by purchasing an N5260A controller test set with test   
heads (Option 110, 120, or 130).

1.  The 5063-9237 kit assumes you have the standard handles 

shipped with the instrument. If you do not have handles, order a 
5063-9224 kit.

PNA Series Network Analyzer (continued)

Содержание PNA E8361C

Страница 1: ... Microwave Network Analyzers PNA E8362C 10 MHz to 20 GHz PNA E8363C 10 MHz to 40 GHz PNA E8364C 10 MHz to 50 GHz PNA E8361C 10 MHz to 67 GHz PNA L N5230C 300 kHz to 6 13 5 or 20 GHz 10 MHz to 20 40 or 50 GHz Configuration Guide ...

Страница 2: ...ands on all customer specifications Conforms to ISO 17025 and ISO 9001 ANSI Z540 compliant calibration Option A6J Complete set of measurements which tests unit to manufacturer s published specifications Includes pre and post adjustment data with measurement uncertainty information compliant to the ANSI NCSL Z540 standard Documentation The PNA Series instruments are equipped with an Online Help sys...

Страница 3: ...ires 014 Pulse antenna mm wave Option H08 Pulsed RF measurement capability E8362C H08 E8363C H08 E8364C H08 E8361C H08 Requires 014 080 Option H11 recommended Option H11 IF access for antenna pulsed RF and mm wave measurements E8362C H11 E8363C H11 E8364C H11 E8361C H11 Requires 014 UNL 080 and 081 Accessories Option 1CM Rack mount kit for use without handles E8362C 1CM E8363C 1CM E8364C 1CM E8361...

Страница 4: ...ource a hard disk drive USB interfaces and an 8 4 LCD color touch screen display The E8362C has 3 5 mm male 50 ohm test ports The E8363C 64C have 2 4 mm male 50 ohm test ports The E8361C has 1 85 mm male 50 ohm test ports Included with each instrument is a mouse and a keyboard U S Test set and power configuration options Configurable test set Option 014 Provides six front panel access loops Three ...

Страница 5: ... using an external test set Only standard measurement class is available in the multiport analyzer mode Pulse antenna mm wave Pulsed RF measurement capability Option H08 Provides software to set up and control pulsed RF measurements with point in pulse capability The software sets the coefficient of the PNA s digital IF filter to null out unwanted spectral components enables the IF gates provided ...

Страница 6: ...plitter Reference receiver Reference receiver Measurement receivers Port 1 Port 2 A B R1 R2 1 Source attenuator for E8362 3 4C is 60 dB in 10 dB steps 2 Source attenuator for E8361C is 50 dB in 10 dB steps Source Switch Reference receiver Reference receiver Measurement receivers Port 1 Port 2 A B R1 R2 Source attenuator1 Source attenuator1 Bias tee Bias tee ...

Страница 7: ...ption UNL and 014 Source Switch Reference receiver Reference receiver Measurement receivers Port 1 Port 2 A B R1 R2 Source Switch Reference receiver Reference receiver Measurement receivers Port 1 Port 2 Bias tee Source attenuator1 A Bias tee Source attenuator1 B R1 R2 1 Source attenuator for E8362 3 4C is 60 dB in 10 dB steps 2 Source attenuator for E8361C is 50 dB in 10 dB steps ...

Страница 8: ... steps Receiver attenuator2 Rcvr B in Rcvr A in Cplr arm SRC out Cplr thru Source out Rcvr R2 in Cplr thru SRC out Rcvr R1 in Source out Option 081 Fully optioned active device or mixer converter test configuration Options 014 UNL 016 080 081 1 Source attenuator for E8362 3 4C is 60 dB in 10 dB steps Source attenuator for E8361C is 50 dB in 10 dB steps 2 Receiver attenuator for E8362 3 4C is 35 dB...

Страница 9: ...e out Option 081 DUT 40 dBm 30 dBm 15 dBm 30 dBm 30 dBm 15 dBm 15 dBm 40 dBm 15 dBm preamp Source attenuator1 Source attenuator1 30 dBm 30 dBm 1 Source attenuator for E8362 3 4C is 60 dB in 10 dB steps 2 Receiver attenuator for E8362 3 4C is 35 dB in 5 dB steps Power levels shown on the diagram are damage levels At a minimum keep power levels 6 dB below damage level For optimal performance keep th...

Страница 10: ...tion H111 A LO Option H11 Multipliers 1 2 Multipliers 1 2 4 YIG source 8 33 MHz reference Offset LO Phase locked loop Vtune Option 080 Option 081 Option 014 Option 014 Option 014 Front Rear Aux RF out 2 to 20 GHz Aux LO out 2 to 20 GHz Offset receiver IF gate IF gate Fully optioned pulse RF antenna or mm wave configuration Options 014 UNL 016 080 081 H11 1 Option H11 IF gate controls and external ...

Страница 11: ... for the correct part number http na tm keysight com pna documents html 4 Port measurement application Option 550 Available for E8361C E8362C 3C 4C Enables full 4 port error correction and differential measurements Option 014 and external test set required User installable N port capabilities Option 551 Available for E8361C E8362C 3C 4C Adds full N port error correction and measurement capabilitie...

Страница 12: ...ption 520 10 MHz 50 GHz 2 port standard test set N5230C 520 Option 525 10 MHz 50 GHz 2 port configurable test set and extended power range N5230C 525 Measurement applications Option 010 Time domain for 6 GHz model N5231C 010 Option 010 Time domain for 13 5 20 40 or 50 GHz model N5230C 010 Option 080 Frequency offset measurements N5230C 080 Option 082 Scalar calibrated converter measurements N5230C...

Страница 13: ...ceiver Measurement receivers Port 1 Port 2 A B R1 R2 PNA L Series test set and power configuration options The PNA L is an integrated vector network analyzer equipped with a built in S parameter test set one or two synthesized sources used for device stimulus a hard disk drive USB interfaces and an 8 4 LCD color touch screen display 40 and 50 GHz models have 2 4 mm ruggedized male 50 ohm connector...

Страница 14: ...mode to any PNA L network analyzer with Option x25 x45 or x46 configurable test set which enables full 4 port error correction and measurement capabili ties using an external test set Only standard measurement class is available in the multiport analyzer mode N port capabilities Option 551 Adds multiport analyzer mode to any PNA network analyzer with Option x25 x45 or x46 configurable test set whi...

Страница 15: ...er range to 20 GHz PNA L 2 ports N5230C 220 N5230CU 922 No Add configurable test set and extended power range to 40 or 50 GHz PNA L 2 ports N5230C 420 or 520 N5230CU 941 No Add configurable test set and extended power range to 13 4 or 20 GHz PNA L 4 prots N5230C 140 or 240 N5230CU 926 No Add internal second source to 13 5 GHz PNA L 4 ports N5230C 145 N5230CU 928 No Add internal second source to 20...

Страница 16: ...t com find contactus BP 9 7 17 DEKRA Certified ISO9001 Quality Management System www keysight com go quality Keysight Technologies Inc DEKRA Certified ISO 9001 2015 Quality Management System Evolving Since 1939 Our unique combination of hardware software services and people can help you reach your next breakthrough We are unlocking the future of technology From Hewlett Packard to Agilent to Keysig...

Отзывы: