Measurement applications

 

Time-domain capability (Option 010) 

  For viewing reflection and transmission responses in time or    
  distance domain.

 

Frequency offset (Option 080) 

  This option enables the PNA Series microwave network analyzers 
  to set the source frequency independently from where the    

receivers are tuned. This ability is important for two general    
classes of devices: mixers (and converters) and amplifiers.    
Option 080 provides a very basic user interface. 

 

Reference receiver switch (Option 081) 

  Option 081 adds a solid-state internal RF transfer switch in the  

 R1 reference-receiver path (see PNA Series Microwave Data    
Sheet literature number 5989-7605EN for a block diagram). The  
 switch allows the instrument to easily switch between standard    
S-parameter (non-frequency-offset) measurements and frequency  
 offset measurements such as relative phase or absolute group  
 delay that require an external reference mixer. The user can set  
 the switch manually or remotely, but it is best used with the    
frequency-converter application (Option 083), where it is controlled  
 automatically during the vector-mixer calibration procedure    
and subsequent measurements.

 

Scalar-calibrated converter measurements  

  (Option 082)

  With a simple setup and calibration, this application provides  
  the highest accuracy for conversion-loss (or gain) measurements  
  by combining one-port and power-meter calibrations to remove  
  mismatch errors. Option 080 required. 

  

Vector- and scalar-calibrated converter 
measurements (Option 083)  

 

  This converter measurement adds an intuitive and easy-to-use   

user interface, advanced calibration choices that provide    
exceptional amplitude and phase accuracy, and control of    
external signal sources for use as local oscillators. Mixer    
calibration techniques include scalar-mixer calibration and    
vector-mixer calibration (requires Option 081). Finally, the    
frequency-converter application supports all of Keysight’s  
 major signal source families. 

 

Embedded LO Measurements (Option 084) 

  This option tunes the PNA receivers to the output frequency of   

the converter under test, without the need for access to internal  
 LOs or a common reference signal. For converters with embed-  
ded LOs, this option enables measurements of match-corrected  
 conversion loss/gain (requires Option 082 or 083), and absolute  
 group delay (requires Option 083).

PNA Series Network Analyzer

The microwave PNA Series instruments are integrated vector network 
analyzers equipped with a built-in S-parameter test set, synthesized 
source, a hard disk drive, USB interfaces, and an 8.4” LCD color 
touch screen display. The E8362C has 3.5 mm male 50-ohm test 
ports. The E8363C/64C have 2.4 mm male 50-ohm test ports. The 
E8361C has 1.85 mm male 50-ohm test ports. Included with each 
instrument is a mouse and a keyboard (U.S.) 

Test set and power configuration options

 

Configurable test set (Option 014)

 

 Provides six front panel access loops. Three access loops are   
for port one and three for port two. The loops provide access   
to the signal path between (a) the source output and the  

 

 reference receiver, (b) the source output and directional coupler  
 thru arm and (c) the coupled arm of the directional coupler and  
 the port receiver. This option provides the capability to improve  
 instrument sensitivity for measuring low-level signals, to    
reverse the directional coupler to achieve even more dynamic

  range or to add components and other peripheral instruments  

 for a variety of measurement applications. (see PNA Series    
Microwave Data Sheet literature number 5989-7605EN for a   
basic block diagram)

 

 

Extended power range and bias-tees  

 (Option  UNL)

  

 Adds two 60 dB step attenuators and two bias-tees to the    
E8362/3/4C. Adds two 50 dB step attenuators and two bias-tees  
 to the E8361C. A step attenuator and bias-tee set is inserted   
between the source and test port one and another set  

 

 between the source and test port two. (see PNA Series  

 

 Microwave Data Sheet literature number 5989-7605EN for a    
basic block diagram)

 

Add receiver attenuators (Option 016)

 

  An attenuator is added between each test port and its  

 

 corresponding receiver. Two 35 dB step attenuators are added   
to the E8362/3/4C. Two 50 dB step attenuators are added to    
the E8361C (see PNA Series Microwave Data Sheet literature   
number 5989-7605EN for a basic block diagram). 

 

High-power test set (Model E836xCH85) 

  This configuration combines options that are often necessary   

for high power measurements (UNL

1

, 014, 016, 080, 081).    

 The only difference between ordering Option H85 versus a 

  combination of the options listed above is the source  

 

 attenuator option UNL. Standard UNL includes two source    
attenuators and two bias-tees. Option H85 includes the two    
source attenuators, but not the bias-tees, as the bias-tees are  
 the power-limiting factor in the network analyzer test set. The    
maximum power at the test port is +43 dBm (< 20 GHz), and 

  +40 dBm (> 20 GHz).  
  Option 080, frequency-offset mode, is included in Option H85  

 because it manages the phase-locking internally (instead of    
depending on the R1 receiver). So if you need to use external   
components in the path of the R1 receiver, it makes the  

 

 measurements simpler and more robust. 

1.  UNL does not include bias-tees. Only includes source attenuators 

Содержание PNA E8361C

Страница 1: ... Microwave Network Analyzers PNA E8362C 10 MHz to 20 GHz PNA E8363C 10 MHz to 40 GHz PNA E8364C 10 MHz to 50 GHz PNA E8361C 10 MHz to 67 GHz PNA L N5230C 300 kHz to 6 13 5 or 20 GHz 10 MHz to 20 40 or 50 GHz Configuration Guide ...

Страница 2: ...ands on all customer specifications Conforms to ISO 17025 and ISO 9001 ANSI Z540 compliant calibration Option A6J Complete set of measurements which tests unit to manufacturer s published specifications Includes pre and post adjustment data with measurement uncertainty information compliant to the ANSI NCSL Z540 standard Documentation The PNA Series instruments are equipped with an Online Help sys...

Страница 3: ...ires 014 Pulse antenna mm wave Option H08 Pulsed RF measurement capability E8362C H08 E8363C H08 E8364C H08 E8361C H08 Requires 014 080 Option H11 recommended Option H11 IF access for antenna pulsed RF and mm wave measurements E8362C H11 E8363C H11 E8364C H11 E8361C H11 Requires 014 UNL 080 and 081 Accessories Option 1CM Rack mount kit for use without handles E8362C 1CM E8363C 1CM E8364C 1CM E8361...

Страница 4: ...ource a hard disk drive USB interfaces and an 8 4 LCD color touch screen display The E8362C has 3 5 mm male 50 ohm test ports The E8363C 64C have 2 4 mm male 50 ohm test ports The E8361C has 1 85 mm male 50 ohm test ports Included with each instrument is a mouse and a keyboard U S Test set and power configuration options Configurable test set Option 014 Provides six front panel access loops Three ...

Страница 5: ... using an external test set Only standard measurement class is available in the multiport analyzer mode Pulse antenna mm wave Pulsed RF measurement capability Option H08 Provides software to set up and control pulsed RF measurements with point in pulse capability The software sets the coefficient of the PNA s digital IF filter to null out unwanted spectral components enables the IF gates provided ...

Страница 6: ...plitter Reference receiver Reference receiver Measurement receivers Port 1 Port 2 A B R1 R2 1 Source attenuator for E8362 3 4C is 60 dB in 10 dB steps 2 Source attenuator for E8361C is 50 dB in 10 dB steps Source Switch Reference receiver Reference receiver Measurement receivers Port 1 Port 2 A B R1 R2 Source attenuator1 Source attenuator1 Bias tee Bias tee ...

Страница 7: ...ption UNL and 014 Source Switch Reference receiver Reference receiver Measurement receivers Port 1 Port 2 A B R1 R2 Source Switch Reference receiver Reference receiver Measurement receivers Port 1 Port 2 Bias tee Source attenuator1 A Bias tee Source attenuator1 B R1 R2 1 Source attenuator for E8362 3 4C is 60 dB in 10 dB steps 2 Source attenuator for E8361C is 50 dB in 10 dB steps ...

Страница 8: ... steps Receiver attenuator2 Rcvr B in Rcvr A in Cplr arm SRC out Cplr thru Source out Rcvr R2 in Cplr thru SRC out Rcvr R1 in Source out Option 081 Fully optioned active device or mixer converter test configuration Options 014 UNL 016 080 081 1 Source attenuator for E8362 3 4C is 60 dB in 10 dB steps Source attenuator for E8361C is 50 dB in 10 dB steps 2 Receiver attenuator for E8362 3 4C is 35 dB...

Страница 9: ...e out Option 081 DUT 40 dBm 30 dBm 15 dBm 30 dBm 30 dBm 15 dBm 15 dBm 40 dBm 15 dBm preamp Source attenuator1 Source attenuator1 30 dBm 30 dBm 1 Source attenuator for E8362 3 4C is 60 dB in 10 dB steps 2 Receiver attenuator for E8362 3 4C is 35 dB in 5 dB steps Power levels shown on the diagram are damage levels At a minimum keep power levels 6 dB below damage level For optimal performance keep th...

Страница 10: ...tion H111 A LO Option H11 Multipliers 1 2 Multipliers 1 2 4 YIG source 8 33 MHz reference Offset LO Phase locked loop Vtune Option 080 Option 081 Option 014 Option 014 Option 014 Front Rear Aux RF out 2 to 20 GHz Aux LO out 2 to 20 GHz Offset receiver IF gate IF gate Fully optioned pulse RF antenna or mm wave configuration Options 014 UNL 016 080 081 H11 1 Option H11 IF gate controls and external ...

Страница 11: ... for the correct part number http na tm keysight com pna documents html 4 Port measurement application Option 550 Available for E8361C E8362C 3C 4C Enables full 4 port error correction and differential measurements Option 014 and external test set required User installable N port capabilities Option 551 Available for E8361C E8362C 3C 4C Adds full N port error correction and measurement capabilitie...

Страница 12: ...ption 520 10 MHz 50 GHz 2 port standard test set N5230C 520 Option 525 10 MHz 50 GHz 2 port configurable test set and extended power range N5230C 525 Measurement applications Option 010 Time domain for 6 GHz model N5231C 010 Option 010 Time domain for 13 5 20 40 or 50 GHz model N5230C 010 Option 080 Frequency offset measurements N5230C 080 Option 082 Scalar calibrated converter measurements N5230C...

Страница 13: ...ceiver Measurement receivers Port 1 Port 2 A B R1 R2 PNA L Series test set and power configuration options The PNA L is an integrated vector network analyzer equipped with a built in S parameter test set one or two synthesized sources used for device stimulus a hard disk drive USB interfaces and an 8 4 LCD color touch screen display 40 and 50 GHz models have 2 4 mm ruggedized male 50 ohm connector...

Страница 14: ...mode to any PNA L network analyzer with Option x25 x45 or x46 configurable test set which enables full 4 port error correction and measurement capabili ties using an external test set Only standard measurement class is available in the multiport analyzer mode N port capabilities Option 551 Adds multiport analyzer mode to any PNA network analyzer with Option x25 x45 or x46 configurable test set whi...

Страница 15: ...er range to 20 GHz PNA L 2 ports N5230C 220 N5230CU 922 No Add configurable test set and extended power range to 40 or 50 GHz PNA L 2 ports N5230C 420 or 520 N5230CU 941 No Add configurable test set and extended power range to 13 4 or 20 GHz PNA L 4 prots N5230C 140 or 240 N5230CU 926 No Add internal second source to 13 5 GHz PNA L 4 ports N5230C 145 N5230CU 928 No Add internal second source to 20...

Страница 16: ...t com find contactus BP 9 7 17 DEKRA Certified ISO9001 Quality Management System www keysight com go quality Keysight Technologies Inc DEKRA Certified ISO 9001 2015 Quality Management System Evolving Since 1939 Our unique combination of hardware software services and people can help you reach your next breakthrough We are unlocking the future of technology From Hewlett Packard to Agilent to Keysig...

Отзывы: