background image

11

Upgrade kits are available to add options after initial purchase. To order 
an upgrade kit for the PNA series, order the analyzer’s model number fol-
lowed by a “U”, then indicate the option to be added 
(for example, E8362CU-010). The current configuration and serial num-
ber of the instrument to be retrofitted are required as part of  
the order.

 

Time-domain (Option 010)  

  User installable.

 

Configurable test set (Option 014)

  Provides six front-panel RF access loops.  

  Includes installation at a Keysight service center.

 

Receiver attenuators (Option 016) 

  Includes installation at a Keysight service center.

 

Frequency range upgrade to an E8363C  

  (40 GHz) PNA (Option 040/041) 

  Available only for the E8362C. Includes 
  installation at a Keysight service center.

 

Frequency range upgrade to an E8364C  

  (50 GHz) PNA (Option 050/051) 

  Available only for the E8362C and E8363C.
  Includes installation at a Keysight service center.

 Frequency range upgrade to an E8361C  

  (67 GHz) PNA (Option 067/068) 

  Available only for the E8363C and E8364C.
  Includes installation at a Keysight service center.

 Frequency-offset (Option 080)  

  Includes installation at a Keysight service center.

 

External reference switch (Option 081) 

  Includes installation at a Keysight service center.

 

Scalar-calibrated converter measurements  

  (Option 082) 

  User installable. Option 080 required.

 

Frequency converter measurement  

  application (Option 083)   

  User installable. Option 080 and 081 required.  

 

Embedded LO Measurements (Option 084) 

 Advanced software tuning that provides absolute group delay of  
 converters with embedded LOs without the need for access to a  
 common reference signal. The measurement result is the same as  
 locking the DUT LO to the reference mixer LO. (Options 080    
and 083 required) Requires firmware A.07.05 and above plus   
1.1 GHz CPU board.

A/B to C model upgrades

 

Order E8361AU-221, E8362BU-221, E8363BU-221, or E8364BU-221

Note: 
1.  GHz CPU is required to upgrade. Please refer to Customer Support 

Service Guides for the correct part number http://na.tm.keysight.com/
pna/documents.html

 

4-Port measurement application (Option 550) 

  (Available for E8361C, E8362C/3C/4C) 
  Enables full 4-port error correction and differential 
  measurements. Option 014 and external test set required.  
  User installable.

 

N-port capabilities (Option 551) 

  (Available for E8361C, E8362C/3C/4C) 
  Adds full N-port error correction and measurement 
  capabilities. Option 014 and external test set required.  

 

  User installable.

 

Extended power range (Option UNL) 

  Adds a step attenuator and a bias-tee between source and    

each test port. Includes installation at a Keysight service center.

 

Pulsed-RF measurement capability  

  (Option H08) 

  Provides software to set up and control pulsed-RF 
  measurements using narrowband detection, with point-in-pulse  
  and pulse-profile capability. User installable.

 IF access (Option H11)

  Provides hardware for antenna, point-in-pulse, and millimeter- 
  wave measurements. Adds rear-panel RF and LO outputs,    
  external IF inputs, and IF gates (gates enabled with Option H08).  
  Includes installation at a Keysight service center.

 

High-power test set (Option H85)

  Removes bias tees for higher test port power-handling capability.  

 Options UNL, 014, 016, 080, and 081 are required. Includes    
installation at a Keysight Service Center.

Calibration Software Licenses

 

Perpetual license for built-in performance  

  test software for Keysight inclusive cal  
  (Option 897)

  Adds built-in performance testing and calibration software 
  for self-maintainers. Requires additional equipment. See    

the analyzer’s Service Guide for more information on 

  equipment required.

 Perpetual license for built-in performance  

  test software for standards compliant cal  
  (Option 898)

  Adds built-in performance testing and calibration software 
  for self-maintainers. Requires additional equipment. See    

the analyzer’s Service Guide for more information on 

  equipment required.

PNA Series Network Analyzer (continued)

Upgrade kits

Upgrade kits for the PNA Series E8361C, E8362C, E8363C, E8364C

1.  Note: For applications, measurement accessories, and general 

accessories please see Keysight PNA Family Network Analyzers 
Configuration Guide, part number 5990-7745EN.

Содержание PNA E8361C

Страница 1: ... Microwave Network Analyzers PNA E8362C 10 MHz to 20 GHz PNA E8363C 10 MHz to 40 GHz PNA E8364C 10 MHz to 50 GHz PNA E8361C 10 MHz to 67 GHz PNA L N5230C 300 kHz to 6 13 5 or 20 GHz 10 MHz to 20 40 or 50 GHz Configuration Guide ...

Страница 2: ...ands on all customer specifications Conforms to ISO 17025 and ISO 9001 ANSI Z540 compliant calibration Option A6J Complete set of measurements which tests unit to manufacturer s published specifications Includes pre and post adjustment data with measurement uncertainty information compliant to the ANSI NCSL Z540 standard Documentation The PNA Series instruments are equipped with an Online Help sys...

Страница 3: ...ires 014 Pulse antenna mm wave Option H08 Pulsed RF measurement capability E8362C H08 E8363C H08 E8364C H08 E8361C H08 Requires 014 080 Option H11 recommended Option H11 IF access for antenna pulsed RF and mm wave measurements E8362C H11 E8363C H11 E8364C H11 E8361C H11 Requires 014 UNL 080 and 081 Accessories Option 1CM Rack mount kit for use without handles E8362C 1CM E8363C 1CM E8364C 1CM E8361...

Страница 4: ...ource a hard disk drive USB interfaces and an 8 4 LCD color touch screen display The E8362C has 3 5 mm male 50 ohm test ports The E8363C 64C have 2 4 mm male 50 ohm test ports The E8361C has 1 85 mm male 50 ohm test ports Included with each instrument is a mouse and a keyboard U S Test set and power configuration options Configurable test set Option 014 Provides six front panel access loops Three ...

Страница 5: ... using an external test set Only standard measurement class is available in the multiport analyzer mode Pulse antenna mm wave Pulsed RF measurement capability Option H08 Provides software to set up and control pulsed RF measurements with point in pulse capability The software sets the coefficient of the PNA s digital IF filter to null out unwanted spectral components enables the IF gates provided ...

Страница 6: ...plitter Reference receiver Reference receiver Measurement receivers Port 1 Port 2 A B R1 R2 1 Source attenuator for E8362 3 4C is 60 dB in 10 dB steps 2 Source attenuator for E8361C is 50 dB in 10 dB steps Source Switch Reference receiver Reference receiver Measurement receivers Port 1 Port 2 A B R1 R2 Source attenuator1 Source attenuator1 Bias tee Bias tee ...

Страница 7: ...ption UNL and 014 Source Switch Reference receiver Reference receiver Measurement receivers Port 1 Port 2 A B R1 R2 Source Switch Reference receiver Reference receiver Measurement receivers Port 1 Port 2 Bias tee Source attenuator1 A Bias tee Source attenuator1 B R1 R2 1 Source attenuator for E8362 3 4C is 60 dB in 10 dB steps 2 Source attenuator for E8361C is 50 dB in 10 dB steps ...

Страница 8: ... steps Receiver attenuator2 Rcvr B in Rcvr A in Cplr arm SRC out Cplr thru Source out Rcvr R2 in Cplr thru SRC out Rcvr R1 in Source out Option 081 Fully optioned active device or mixer converter test configuration Options 014 UNL 016 080 081 1 Source attenuator for E8362 3 4C is 60 dB in 10 dB steps Source attenuator for E8361C is 50 dB in 10 dB steps 2 Receiver attenuator for E8362 3 4C is 35 dB...

Страница 9: ...e out Option 081 DUT 40 dBm 30 dBm 15 dBm 30 dBm 30 dBm 15 dBm 15 dBm 40 dBm 15 dBm preamp Source attenuator1 Source attenuator1 30 dBm 30 dBm 1 Source attenuator for E8362 3 4C is 60 dB in 10 dB steps 2 Receiver attenuator for E8362 3 4C is 35 dB in 5 dB steps Power levels shown on the diagram are damage levels At a minimum keep power levels 6 dB below damage level For optimal performance keep th...

Страница 10: ...tion H111 A LO Option H11 Multipliers 1 2 Multipliers 1 2 4 YIG source 8 33 MHz reference Offset LO Phase locked loop Vtune Option 080 Option 081 Option 014 Option 014 Option 014 Front Rear Aux RF out 2 to 20 GHz Aux LO out 2 to 20 GHz Offset receiver IF gate IF gate Fully optioned pulse RF antenna or mm wave configuration Options 014 UNL 016 080 081 H11 1 Option H11 IF gate controls and external ...

Страница 11: ... for the correct part number http na tm keysight com pna documents html 4 Port measurement application Option 550 Available for E8361C E8362C 3C 4C Enables full 4 port error correction and differential measurements Option 014 and external test set required User installable N port capabilities Option 551 Available for E8361C E8362C 3C 4C Adds full N port error correction and measurement capabilitie...

Страница 12: ...ption 520 10 MHz 50 GHz 2 port standard test set N5230C 520 Option 525 10 MHz 50 GHz 2 port configurable test set and extended power range N5230C 525 Measurement applications Option 010 Time domain for 6 GHz model N5231C 010 Option 010 Time domain for 13 5 20 40 or 50 GHz model N5230C 010 Option 080 Frequency offset measurements N5230C 080 Option 082 Scalar calibrated converter measurements N5230C...

Страница 13: ...ceiver Measurement receivers Port 1 Port 2 A B R1 R2 PNA L Series test set and power configuration options The PNA L is an integrated vector network analyzer equipped with a built in S parameter test set one or two synthesized sources used for device stimulus a hard disk drive USB interfaces and an 8 4 LCD color touch screen display 40 and 50 GHz models have 2 4 mm ruggedized male 50 ohm connector...

Страница 14: ...mode to any PNA L network analyzer with Option x25 x45 or x46 configurable test set which enables full 4 port error correction and measurement capabili ties using an external test set Only standard measurement class is available in the multiport analyzer mode N port capabilities Option 551 Adds multiport analyzer mode to any PNA network analyzer with Option x25 x45 or x46 configurable test set whi...

Страница 15: ...er range to 20 GHz PNA L 2 ports N5230C 220 N5230CU 922 No Add configurable test set and extended power range to 40 or 50 GHz PNA L 2 ports N5230C 420 or 520 N5230CU 941 No Add configurable test set and extended power range to 13 4 or 20 GHz PNA L 4 prots N5230C 140 or 240 N5230CU 926 No Add internal second source to 13 5 GHz PNA L 4 ports N5230C 145 N5230CU 928 No Add internal second source to 20...

Страница 16: ...t com find contactus BP 9 7 17 DEKRA Certified ISO9001 Quality Management System www keysight com go quality Keysight Technologies Inc DEKRA Certified ISO 9001 2015 Quality Management System Evolving Since 1939 Our unique combination of hardware software services and people can help you reach your next breakthrough We are unlocking the future of technology From Hewlett Packard to Agilent to Keysig...

Отзывы: