Source Signal Path Insertion Loss Test
1. Connect the RF Flex cables to the Test Port and RCVR OUT port indicated
. The expected results should be similar to
Figure 6
4
Source IN to Ports 5-16 Path Response
Table 2
2
Source Signal Path Connections and Commands
Path #
RF Path
Description
Control Mode
<Address>.<Data>
Path Components
Insertion Loss
(typical)
1
Source IN to Port 5
a
0.2
P5 CPLR, S100
2
Source IN to Ports 9
0.4
P13 CPLR, S100
3
Source IN to Port 13
0.8
P5 CPLR, S100
4
Source IN to Port 6
16.2
P6 CPLR, S200
5
Source IN to Port10
16.4
P10 CPLR, S200
6
Source IN to Port 14
16.8
P14 CPLR, S200
7
Source IN to Port 7
32.2
P7 CPLR, S300
8
Source IN to Port 11
32.4
P11 CPLR, S300
9
Source IN to Port 15
32.8
P15 CPLR, S300
10
Source IN to Port 8
64.2
P8 CPLR, S400
11
Source IN to Port 12
64.4
P12 CPLR, S400
12
Source IN to Port 16
64.8
P16 CPLR, S400
a. Use the Source IN port associated with this group of test ports.