background image

 

IOCB1616 Installation Guide - Aurora 

The IOCB1616 is an auxiliary I/O control board with 16 inputs and 16 outputs. Designed 
for custom applications, the IOCB1616 connects to either a Keyscan 4 door or 8 door 
control unit. The board's inputs and outputs connected on the same IOCB network can be 
used with timers, schedules, or be custom assignable to fit most needs without a reader. 
The CA4500 and the CA8500 each supports up to four IOCB1616 boards for a total of 64 
inputs and outputs.  

Figure 1 – IOCB1616 Overview 

CA4500

or

CA8500

IOCB

1616

IOCB

1616

IOCB

1616

IOCB

1616

Control

Board

16

Inputs

16

Inputs

16

Inputs

16

Inputs

16

Outputs

16

Outputs

16

Outputs

16

Outputs

Maximum 

64 inputs 

per control 

board

Maximum 

64 outputs 
per control 

board

RS485

RS485

Maximum distance from control board to last IOCB1616 is 2000 ft (609.6 m)

KI-00463E-07-12

 

The following lists some real-world examples of how the IOCB1616 may be employed: 

 

Monitor door inputs and use request to exit devices without a reader assignment and 
trigger a sounder such as a siren or a sound alert. 

 

Trigger an auxiliary, third-party product such as an alarm panel or a CCTV product 
that starts a camera recording on a digital input trigger by using an optional output 

OCB-8 board. 

 

Monitor parking lot exit gates without readers in which timing is required. 

 

Use input(s) to trigger a third party product by using an optional OCB-8 output control 

board. 

 

In sensitive areas where a single PIR motion detector may be triggered by air 
coolness or heat drafts, the IOCB1616 would allow the installation of two separate 
PIRs in the same area with conditional “AND” input programming so that both PIRs 
must be in alarm before firing an output to prevent false alarms. 

 

Customize input triggering output with timing for special applications such as 
switching lights, HVAC, etc. 

These are just some of the possible uses. Please note that the IOCB1616 cannot be 
connected to a CA250. 

Contents 

 

Parts List 

Operating Modes 

 

IOCB1616 I/O Board 

Software Setup 

 

 

 

Hardware 

11 

 

 

 

Содержание Aurora IOCB1616

Страница 1: ...may be employed Monitor door inputs and use request to exit devices without a reader assignment and trigger a sounder such as a siren or a sound alert Trigger an auxiliary third party product such as...

Страница 2: ...he door contact is left open after the associated input time has expired 05 Delayed Input Delayed Output If the input is triggered the alarm is delayed The input is delayed by the specified input time...

Страница 3: ...puter room lights As soon as motion is detected in the room Output 2 is triggered and remains active for the duration of Output 2 s specified time If motion is still detected the output remains active...

Страница 4: ...tion when multiple inputs are assigned to a common output any one input fires the output And Condition With the AND condition when two multiple points are assigned to any common output both points nee...

Страница 5: ...n the site in the Hardware Setup directory screen 2 From the Hardware Setup screen double click on the control unit that is connected to the IOCB1616 in the All Hardware screen 3 Select the IOCB1616 t...

Страница 6: ...OCB Output 1 or the first output to be named 3 In the text box enter a name or description appropriate for the output 4 If you are applying a delay for this output double click on the output under the...

Страница 7: ...and the row with the default Input Output is not applicable set the Mode column for that row to Not Used The following table illustrates an example where the default Input 3 is not assigned to Output...

Страница 8: ...tting on Not Used If you make an error or need to clear the assignment select Clear Operator and Secondary Input 4 Under the Secondary Input column double click on the highlighted row and choose the d...

Страница 9: ...ect the IOCB Devices tab 3 Below the IOCB Inputs heading click in the box to the left of the access control unit IOCB Input The box has an x when selected If you are assigning multiple IOCB inputs to...

Страница 10: ...same schedule click in the box of each applicable output The box has an x when selected 4 Click on the symbol to the right of Schedule and select the schedule from the drop down list 5 Click on the As...

Страница 11: ...e 1 reviews the Input Output assignments and table reviews the input supervision selections Jumper Off Off 0 Jumper On On 1 5 4 3 2 1 J17 Jumper Settings Jumper Pins KI 00387E 10 11 J17 Jumper Setting...

Страница 12: ...able IOCB1616 function for PC1097 or later control boards is set in the Aurora software from the Hardware Setup Additional Settings screen under the Hardware Settings heading To enable the control boa...

Страница 13: ...in Standoffs Cover Locking Screw Cover Locking Screw Cover Locking Screw Cover Locking Screw Alternate Locations for Optional OCB 8s KI 00388E 10 11 Dual IOCB1616 Circuit Boards Front View Cover not s...

Страница 14: ...J11 J12 J13 J14 J15 J16 H1 H2 Max Current 400 mA Normal Reversed 1 to 8 9 to 16 Input Output Control Board Short J18 on last IOCB only PROM Ver RX TX Gnd 12V AUX POWER Supervised Inputs 1 2 3 4 5 6 16...

Страница 15: ...Lock power and ACU power must be separate supplies Current consumption without low current open collector connected to any device draws 100mA RX TX GND 12V AUX Power IOCB1616 Circuit Board Red Power C...

Страница 16: ...n without low current open collector connected to any device draws 100mA OCB 8 GND 12V J9 Ext Pwr ACU Pwr OCB 8 GND 12V J9 Ext Pwr ACU Pwr Set J9 jumper to Ext Pwr Set J9 jumper to Ext Pwr Second side...

Страница 17: ...n with ACU RX TX GND 12V AUX Power IOCB1616 Circuit Board 1 RX TX GND 12V AUX Power IOCB1616 Circuit Board 2 RX TX RX RX TX TX Refer to the Keyscan Technical Guide for ACU to PC communication ACU Circ...

Страница 18: ...4 5 6 16 15 14 13 12 High Current Open Collector Control Points 2 Amp Max 16 1 Normally Closed Contact Jumper 4 Off 1 Input 1 Door Contact 1 Input 1 Door Contact to Common Return Normally Closed Cont...

Страница 19: ...IOCB1616 PROM Ver RX TX Gnd 12V AUX POWER 2 3 4 5 6 16 15 14 13 12 High Current Open Collector Control Points 2 Amp Max 16 Supervised Inputs 12 VDC Strike 12 VDC Lock Power Auxiliary output device sw...

Страница 20: ...tput 05 Relay 06 Output 06 Relay 07 Output 07 Relay 08 Output 08 Relay 09 Output 09 Relay 10 Output 10 Relay 11 Output 11 Relay 12 Output 12 Relay 13 Output 13 Relay 14 Output 14 Relay 15 Output 15 Re...

Страница 21: ...This page is intentionally blank...

Страница 22: ...Keyscan Inc A Member of the Kaba Group 22 This page is intentionally blank...

Страница 23: ...IOCB1616 Installation Guide Aurora 06 15 23 This page is intentionally blank...

Страница 24: ...4 Keyscan Inc 901 Burns St E Whitby Ontario Canada L1N 0E6 1 888 539 7226 toll free Canada USA 905 430 7226 elsewhere www keyscan ca Technical support hours 9 00 A M to 6 30 P M Eastern Time IOCB1616...

Отзывы: