System Jumper J16 on ACU
The following table outlines jumper settings on the ACU circuit board for enabling
inputs/outputs on J16.
System Jumpers J16
1
J16 -
J
umper Off
Off = 0
Jumper On
On = 1
Jumper
Settings
2
3
4
5
6
7
8
S Y S T E M C O N F I G .
A
J16 -
B
C
D
E
F
G
H
KI-00142E-07-11
System Jumper J16 Inputs/Outputs
PC1094 – PC1095 Circuit Boards
Jumper #
Jumper Setting
Off=0 / On=1
Disable IOCB1616
8
1
Enable IOCB1616
8
0
PC1097 or Later Circuit Boards
The Enable/Disable IOCB1616 function for PC1097 or later control boards is set in the
Aurora software from the Hardware Setup > Additional Settings screen under the Hardware
Settings heading. To enable the control board for an IOCB1616 connection, click in the box
to the left of IOCB. When enabled, the box has an x.
Current Supply and Current Load
The following table lists circuit board and power supply data.
Current Supply and Current Load
Board
Description
Current
DPS-15
ACU - 12 Volts DC output
1.2 A
DPS-15
AUX – 12 Volts DC output
1.2 A
ACU
Current draw
130 mA
OCB-8
Current Draw
230 mA
IOCB1616
No outputs connected
100 mA
IOCB1616
With outputs connected
400 mA
Does not include communication board current draw.