IOCB1616 Outputs with OCB8s
1
2
3
4
5
6
12VDC
GND
TX
RX
J18
J17
5 4 3 2 1
Binary
Address
Relay
9
Relay
10
Relay
11
Relay
12
Relay
13
Relay
14
Relay
15
Relay
16
GND
12V
ACU
PWR
EXT
PWR
J1
OCB
Max.
Current
200 MA
Normal
J8 J7 J6 J5
J1 J2 J3 J4
Reversed
Relay
1
Relay
2
Relay
3
Relay
4
Relay
5
Relay
6
Relay
7
Relay
8
GND
12V
ACU
PWR
EXT
PWR
J1
OCB
Max.
Current
200 MA
Normal
J8 J7 J6 J5
J1 J2 J3 J4
Reversed
Ribbon for
outputs 9-16
Relay 01 = Output 01
Relay 02 = Output 02
Relay 03 = Output 03
Relay 04 = Output 04
Relay 05 = Output 05
Relay 06 = Output 06
Relay 07 = Output 07
Relay 08 = Output 08
Relay 09 = Output 09
Relay 10 = Output 10
Relay 11 = Output 11
Relay 12 = Output 12
Relay 13 = Output 13
Relay 14 = Output 14
Relay 15 = Output 15
Relay 16 = Output 16
Outputs can be used to activate a lock, pre-alert sounder, etc.
Door Strike
Output 2
Pre-Alert
Output 1
Note: OCB-8 relay boards are used in cases were isolation circuit is preferred on
triggering locks with 24 Volts DC draw load or in circuits using sound devices
Normally
Closed
Connect output(s) to
third party inputs such
as: Alarm Inputs points,
DVR inputs, etc...
Output 12
12VDC
ACU Aux Power
DPS-12
+
-
+
-
-
+
+
-
Separate
12 or 24VDC
Power Source
for
1-16 Outputs
H2
H1
Ribbon for
outputs 1-8
Red stripe
Red stripe
Short J18
on last
IOCB1616
KI-00396E-10-11