42 / 72
Repair work
V 1.0
The following is generally valid for changing operating fluids:
Switch the machine off, allow it to cool, disconnect from the mains power supply (have a specialist do this work),
clean and set down vertically on a firm base. Warm or hot operating fluids can be under pressure. Escaping
operating fluids can lead to burns. For this reason, always allow the machine to cool to ambient temperature first.
Secure it from falling over and/or slipping.
7
Repair work
7.1
General points
The following repair work is possible on this machine:
• Replacement of impeller and pump chamber
• Replacement of split ring
The following must always be heeded for this work:
• O-rings and existing sealing gaskets must always be replaced.
• Screw locking devices such as spring washers must always be replaced.
• The tightening torques must be kept.
The following is generally valid for repair work:
Switch the machine off, disconnect from the mains power supply, clean it and set it down horizontally on a firm
base. Secure it from falling over and/or slipping.
Unless otherwise specified, the torque values in the tables must be used. Values for clean, lubricated screws.
Tightening torque [Nm] for screws A2/A4 (friction coefficient = 0.2)
A2/A4, material
class 70
A2/A4,
material
class 80
DIN 912/DIN 933
DIN 912/DIN 933
M6
7 Nm
11.8 Nm
M8
17 Nm
28.7 Nm
M10
33 Nm
58 Nm
M12
57 Nm
100 Nm
M16
140 Nm
245 Nm
M20
273 Nm
494 Nm
7.2
Replacement of various pump parts
Replacing impeller and pump housing
• Loosen the cylinder head screw with hexagon socket on the sealing housing and screw it off.
• Secure the pump housing using suitable aids e.g. lifting devices, and pull it off the sealing housing. Set down
on a safe base.
Содержание Aqualift F XXL 400 litres 50 Hz Series
Страница 49: ...KESSEL Aqualift F XXL 400 KESSEL Aqualift F XXL 800 50 Hz 2016 11 010 985 SDS 100...
Страница 53: ...53 72 V 1 0 1 2 KESSEL 1 3 KESSEL 1 4 www kessel de 1 4 1 1 4 2 KESSEL 1 4 3 KESSEL KESSEL...
Страница 54: ...54 72 V 1 0 1 4 4 1 4 5 KESSEL AG Bahnhofstrasse 31 D 85101 Lenting 49845627 0 info kessel de www kessel de...
Страница 55: ...55 72 V 1 0 2 2 1 DIN ANSI 2 2 CE EC EC VDE CE 2 3...
Страница 56: ...56 72 V 1 0 2 4 2 5 2 5 1 EMC 2 5 2 IP 68 2 6...
Страница 57: ...57 72 V 1 0 2 7 2 8 2 9 kW 40dB A 70dB A...
Страница 59: ...59 72 V 1 0 4 4 1 4 2 4 3...
Страница 60: ...60 72 V 1 0 5 5 1 5 2 180mm DIN EN 12050 2 5 2 180mm 60 cm 0 7m s 1 0m s DN150 700 mm 1000mm DN 70...
Страница 61: ...61 72 V 1 0 1 1 5 3 5 4...
Страница 63: ...63 72 V 1 0 5 9 5 2 5 1...
Страница 64: ...64 72 V 1 0 6 6 1 BGV GUV 75 439 EWG AbfG 5a 5B TA 524 02 EC 91 689 EEC 6 2 3000 8000 2...
Страница 65: ...65 72 V 1 0 6 3 3 KESSEL KESSEL 0 1 3 4...
Страница 67: ...67 72 V 1 0...
Страница 68: ...68 72 V 1 0 8 8 1 5 8 2 40 8 3...
Страница 69: ...69 72 V 1 0 9...
Страница 70: ...70 72 V 1 0 2 2 KESSEL...