51
6. Inspection and Maintenance
Please heed the safety instructions in chapter 1.
All power should be disconnected from the system when any main-
tenance or service work is being performed. If the two 9-volt batter-
ies in the control unit are to be replaced, use only 450 mAh types.
Repairs to this system should only be handed by the manufacturer.
The control unit itself requires no maintenance.
Cable connections should be checked for damage.
The SonicControl sensor needs to be cleaned on a regular basis.
Proper operation of the back up / flooding sensor (if included) must
be checked during the semi-annual inspection and maintenance
of the system! This can be done by simply placing the back up /
flood sensor under water (approx 10 cm) which after max 4 seconds
should result in the control unit displaying an optical and audible
alarm.
Every time the oil / coalescence separator is emptied / disposed, the
sensor must be cleaned with warm/hot water*. When a high-pres-
sure jet cleaner is used, maintain a safe distance of 30 cm.
The sensor does not have to be removed for cleaning.
The SonicControl control unit and the sensor are connected
by a cable with a maximum total length of 30 meters. Only
this cable should be used, no other cable is allowed for con-
nection.
Beware of all operations on the vessel or to the sensor housing.
Risk of electrostatic charging due to friction and flow of fluids! Elec-
trostatics is a potential source of ignition of flammable materials or
gases. Sensor housing and cables Clean with damp cloth.
The sensor may not be used with corrosive fluids.
The sensor is maintenance free. In order to assure proper operation
of the entire system, the sensor function should be checked once
per year.
Repairs
The SonicControl system may not be repaired, changed or manip-
ulated. In case the SonicControl is damaged or defective it must be
replaced by a new system.
Disposal
In the case that the SonicControl is damaged or no longer required
and needs to be disposed of, please follow all local and national
disposal regulations in your area.
The SonicControl control unit contains two 9-volt batteries which
should be disposed of properly.
Please follow this all the safety instructions in this operating manual
when operating this system.
The control unit will only display a grease thickness layer 24 hours after being placed into operation due to the fact that the reading
is taken at night
, „-“ will be displayed until then.
Содержание 917821
Страница 31: ...31 009 019...
Страница 32: ...32 Notizen...
Страница 62: ...62 10 Connection Plan...
Страница 63: ...63 009 019...
Страница 64: ...64 Notes...
Страница 94: ...94 10 Pi ces de rechange et accessoires...
Страница 95: ...95 11 Sch ma de connexions 009 019...
Страница 96: ...96 Notes...
Страница 126: ...126 10 Schema di collegamento...
Страница 127: ...127 009 019...
Страница 128: ...128 Note...
Страница 158: ...158 10 Elektrische aansluiting...
Страница 159: ...159 009 019 11 Conformiteitsverklaring...
Страница 160: ...160 Aantekeningen...
Страница 191: ...191 11 Schemat po cze SIE KONTAKT BEZPOTENCJA OWY PRZY CZE STEROWANIA ZDALNEGO CZUJNIK...
Страница 192: ...192 009 019...