www.kesseboehmer.de
20
Betrieb / Operation
Container stop on
Move the table to the desired position
(only possible in
Access the menu via the menu button.
lower half of stroke) Select CST with the UP/DOWN button and open with the M
menu button
Select ON with the UP/DOWN button; press M to confirm
Motor control system confirms with double click
CST is still displayed; it is possible to move to the saved position
Container stop off
Access menu via menu button M
(only possible in
Select CST with the UP/DOWN button and open with M
lower half of stroke) Select OFF with the UP/DOWN button; press M to confirm
Motor control system confirms with single click
Shelf stop on
Move the table to the desired position
(only possible in
Access menu via menu button M
upper half of stroke) Select SST with the UP/DOWN button and open with M
Select ON with the UP/DOWN button; press M to confirm
Motor control system confirms with double click
SST is displayed; -it is possible to move to the saved position
Shelf stop off
Access menu via menu button M
(only possible in
Select SST with the UP/DOWN button and open with M
upper half of stroke) Select OFF with the UP/DOWN button; press M to confirm
Motor control system confirms with single click
Display unit of
Access menu via menu button M
measurement
Select CM/IN with UP/DOWN button and open with M
Change cm/inches
Display flashes
Use the UP/DOWN button to set the unit of measurement
and confirm with M
Display offset
Access menu via menu button M
Set the basic height Select OFS with the UP/DOWN button and open with M
Display flashes
Use the UP/DOWN button to set the height display; confirm
with M