www.kesseboehmer.de
17
Betrieb / Operation
Upward movement
Press and hold UP; display shows table top height in cm
or inches.
Downward movement
Press and hold DOWN; display shows table top height.
Save to memory
Press and hold M for 1 to 3 sec. Then press F1, F2, F3
or F4 within 3 sec.
Confirmation of the saved position by a double clicking sound.
Start from memory
Press F1, F2, F3 or F4 and hold until the desired position
is reached (see height display).
Button lock on/off
Press and hold M for up to 10 sec.
·
The reset position of the drives is located approx. in the middle of the
stroke.
·
The reset position depends on the traversing range and the attachments
of the table.
·
If the table is located above the reset position the table first moves below
the reset position and then from below up to the reset position.
·
If the table is located below the reset position the table moves up to the
reset position.
·
If one column of the table is located above the reset position and the
other column is located below the reset position the column which is
above the reset position first moves below the reset position. Then both
columns are moved from below to the reset position.
·
Each column performs its own reset. This means that if one column is
pushed in further than the other, the column will reach the reset point
sooner and will complete the reset sooner than the other column.
Notice