Technical Reference Manual – SB-293
Printing Date
01838-002 Rev. 3.0
July-1998
Page 5 of 32
Features
The SB-293 Satellite Board expands the capabilities of the PXL-250 Tiger Controller. Depending
upon the application, the SB-293 can add 8 general purpose inputs and 4 general purpose outputs, or
it can add Door Switch and Request to Exit inputs and Door Lock and Alarm outputs for a second
door (one reader per door) with 6 additional general purpose inputs and two additional general
purpose outputs. In a networked access control system, the SB-293 increases the number of doors
that can be managed from 128 to a maximum of 256. Refer to Figure 1 on pages 6 and 7 for a basic
diagram of the PXL-250 access control network, including the SB-293 Satellite Board.
Standard features include:
Second Door Access Control Configuration
•
two doors, one reader per door
(in conjunction with a PXL-250 controller)
•
two door control inputs
−
door switch status
−
request to exit
•
six general purpose inputs
−
one can be user-configured for B-door
Auxiliary RTE
•
two Form C output relays
−
door lock
−
door alarm
•
two general purpose, Form C, output
relays
−
both can be user-configured for Door
Held Open alarm annunciation
Additional Input/Output Configuration
•
one door may use one or two readers
•
eight general purpose inputs
•
four general purpose, Form C, output
relays
Quick Connect Wiring Connectors
•
allows for quick removal of wiring connectors
•
makes it easy to change/upgrade wiring following system installation
Electrical Surge/Transient Protection
•
Transorbs across all inputs and outputs (except relay outputs)
•
MOVs across all relay outputs