NC-485X Network Converter
Application Note
Page 8 of 13
P/N: 01967-001 Rev. C
8. Press <Enter> until the Remote Port parameter is displayed. This value must be
10002
for proper
communication between
Doors
and the LAN-520X. If this value is not
10002
, type
10002
to
overwrite the original value.
NOTE: The Port number should not be changed from 10002 unless multiple PXL networks are on the
same LAN Subnet (see “Using Multiple PXL Networks on the Same LAN Subnet” on page 9) or
instructed to do so by either Keri Systems or Lantronix Technical Support Staff.
9. Press <Enter> until the Change Setup menu appears (see Figure 6).
Figure 6: Correct Channel 2 Configuration Parameters - Slave Unit
10. Press 9 <Enter> to save the assigned Channel 2 configuration parameters. A “Parameters
stored...” message appears and the connection is closed. You may now close the Telnet window.
The Channel 2 configuration parameters are now entered into the LAN-520X’s configuration
table.