NC-485X Network Converter
Application Note
Page 6 of 13
P/N: 01967-001 Rev. C
9. Press <Enter> until the Hostlist parameter is displayed. The Hostlist parameter is only displayed
if the Connect Mode has been set to 2C. This option may be configured for up to 12 remote slave
IP addresses on different LAN subnets. Setting this parameter will designate this unit as a master.
10. Press Y <Enter> to add or change the IP addresses and Port numbers of the slave units. Enter the
IP address and Port number for each slave unit. The Port number should be set to
10002
.
11. Once all the IP addresses and Port numbers have been entered, enter an IP address of 0.0.0.0 to
exit and press N when the “Change Hostlist? (N)” option is displayed (see Figure 5).
12. Press <Enter> until the Change Setup menu appears.
Figure 5: Correct Channel 2 Configuration Parameters - Master Unit
13. Press 9 <Enter> to save the assigned Channel 2 configuration parameters. A “Connection to host
lost” message appears. Click the box to clear the connection lost message, then close the Telnet
window and close the DOS box. The Channel 2 configuration parameters are now entered into the
LAN-520X’s configuration table.