30
LDB-ST1LE Batcher
6.4.14
SERIAL USAGE
Press Enter to begin setup of the Serial Port.
Select Serial Hardware type for standard port. RS-232
is standard. (See SETUP NETWORK CARD for RS485
Modbus option)
Select the Device ID (0-99).
Select the desired Baud Rate.
(If <more> selected, additional baud rates are offered.
9600 is standard)
Select the desired Parity. (NONE is standard)
Set the Handshake. (NONE is standard)
Choose end of line termination. Only choose <CR> if
your external device automatically assigns a line feed for
every <CR> carriage return.
Select "Yes" if the serial port will be used to control a
Hayes compatible modem.
Select the desired Modem Auto Answer mode. Select
YES to setup modem to answer incoming calls.
Enter the Call Out Phone Number to be dialed at "Call
Out Time" or upon "Call On Error/Alarm".
Enter the time of day to perform Call Out transmission.
Select "Yes" to have the unit perform a Call Out
transmission upon error/alarm condition.
Enter the number of redials to be performed on call
out time if busy or no answer. (error/alarm tries until
connected)
Select "Yes" to perform hang-up if there is inactivity for
more than 2 minutes for calls initiated by the LDB-ST1LE.
SERIAL USAGE
SERIAL HARDWARE
RS232 RS485
DEVICE ID
##
BAUD RATE
300 600 1200 <more>
BAUD RATE
2400 4800 9600 19200
PARITY
None Odd Even
HANDSHAKING
None Softwre Hardwre
DEVICE LINE FEED
<CR> <CR+LF>
MODEM CONTROL
No Yes
MODEM AUTO ANSWER
No Yes
CALL OUT PHONE #
0
CALL OUT TIME
##:##:##
CALL ON ERROR/ALARM
No Yes
NUMBER OF REDIALS
0
HANGUP IF 2MIN INACT
No Yes
Advance To
SETUP DATALOG/PRINT
Notes
Display
Sub-menus