8
LDB-ST1LE Batcher
3.2 Batching
Measurements:
A flowmeter measures the actual volume in a liquid line.
Calculations:
• For Flowmeters with Pulse Outputs, Volume flow is calculated using the flowmeter frequency output
and the user entered K-Factor or Linearization Table.
Output Results:
• Display Results
Flow Rate, Batch Total, Non-Resettable Total
• Pulse Output
Total
• Analog Output
Rate or Total
• Relay Outputs
Batch Total, Rate, or Alarms
Applications:
Batching and monitoring flow and total of any liquid. Batching is accomplished via relays and
datalogging is available via serial outputs.
Batching Illustration
Calculations
Pulse Input; Average K-Factor or Linearization Table
input frequency * time scale factor
Volume Flow =
K-Factor
STOP
START
5
0
–
CLEAR
•
MENU
ENTER
HELP
4
PRE 1
3
RATE
2
TOTAL
1
GRAND
6
SCROLL
7
PRE 2
8
9
Flowmeter
Solenoid Valve
F4
F1
F2
F3
8.39” (235mm)
4.00” (101.7mm)
1.06”
(27mm)
1.10”
(28mm)
7.28”
(185mm)
4.92”
(125mm)
0.75”
(19mm)
M20 (5 places)
M16