TS-5700
Service Adj ustment Mode
• Outl ine
ADJ U STM E NT
2)
Menu n u m ber selection
1. The transceiver is adjusted by the normal method
and by a method using the service adjustment
mode (automatic adjustment).
When the [MULTE/CHJ control is turned, the menu
number changes.
3)
Changing the setting data
Setting data can be changed by using the [UP] or
[DOWN] key on the transceiver or the microphone.
2. There are adjustment items of menu numbers 00 to
51 in the service adjustment mode. All adjustment
data are saved in the EEPROM.
4)
Writing data
3. When the service adjustment mode is entered, data
is read from the EEPROM and placed in the CPU
RAM, so it can be modified.
Press the [UP] or [DOWN] key on the transceiver or
the microphone with MENU No.51 to write data.
4. The EEPROM is updated only when data is written
in Menu No. 51.
5 ) Cancel i n g the service adjustment mode
When the [CLR] key is pressed, the normal V FO
mode display returns.
• Operation Proced ure
1 ) E nteri n g the service a dj ustment mode
Notes:
1. Before turning the power on, insert the adjustment
jig into the ACC2 socket.
1. The transceiver can transmit signals in the receiver
adjustment mode. If a microphone is connected to
the transceiver, take special care not to press the
PTT key.
2. Hold down the [ N.R . ] key and [ LSB/USB] key and
turn the [POWER] switch on. The display ( LCD)
shows " ADJUST" and then the adjustment mode
menu.
2. If the power is switched off during adjustment in
the adjustment mode, the adjustment mode is can
celed.
3. After " ADJUST" appears, remove the short plug
from the ACC2 . (The transmitter cannot be ad
justed without removing it.)
Service Adjustment Mode Menu
Menu No.
Fu nction
Description
00
AGC
AGC refe rence voltage ( 1 4 . 1 M H z U S B )
0 1
ALC
ALC refe rence voltage ( 1 4 . 2 M H z U S B )
0 2
S S B SOL t h re s h o l d
( 1 4 1 M H z U S B )
0 3
S-m eter ( S S B )
Start l evel ( S 1 ) sett i n g ( 1 4 1 M H z U S B )
04
S9 level sett i n g ( 1 4 . 1 M H z U S B )
0 5
S9+60dB (fu l l sca le) l eve l sett i n g ( 1 4 . 1 M H z U S B )
0 6
F M SOL t h re s h o l d
(29 1 M H z F M )
07
S-meter ( F M )
Start l evel ( S 1 ) sett i n g (2 9 . 1 M H z F M )
08
F u l l sca l e l evel setti n g (2 9 . 1 M H z F M )
09 - 1 5
N ot use
1 6
SOL VR center
S O L VR center voltage rea d i n g ( 1 4 . 1 M H z)
1 7
I F S H I FT center
IF S H I FT center voltage rea d i n g ( 1 4 . 1 M H z)
1 8
1 DOW protection setti n g
Read d a t a at t h e 1 00W point on t h e R F m e t e r ( 1 4 . 2 M H z U S B )
1 9
50W protection sett i n g
Read data at t h e 5 0 W p o i n t on t h e R F meter ( 1 4 . 2 M H z U S B )
20
25W p rotection sett i n g
R e a d data at t h e 2 5W p o i n t on t h e R F meter ( 1 4 . 2 M H z U S B )
2 1
1 O W p rotection sett i n g
Read data at t h e 1 O W p o i n t o n t h e R F meter ( 1 4 . 2 M H z U S B )
2 2
5 W protection sett i n g
Read d a t a at t h e 5 W point o n the R F m e t e r ( 1 4 . 2 M H z U S B )
23
TGC sett i n g
1 . 8 M H z b a n d ( 1 DOW) ( 1 .840 M H z U S B )
2 4
3 . 5 M H z b a n d ( 1 OOW) (3 . 5 M H z U S B )
25
7 M H z b a n d ( 1 00W) ( 7 . 0 M H z U S B )
26
1 O M H z ba n d ( 1 00W) ( 1 0
1
MHz U S B )
2 7
1 4 M H z b a n d ( 1 OOW) ( 1 4 . 2 M H z U S B )
2 8
1 S M H z b a n d ( 1 OOW) ( 1 8 . 068 M H z U S B )
29
2 1 MHz b a n d ( 1 DOW) ( 2 1 . 0 M H z U S B )
3 0
2 5 M H z b a n d ( 1 OOW) ( 2 4 89 M H z U S B )
3 1
2 8 M H z b a n d ( 1 OOW) ( 2 9 . 69 M H z U S B )
67