49
ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
TK-785
3. High power
1) Set test mode
Power meter Rear
ANT
10.0W
K
±
1.0W
Select “HPOW” in tuning mode. F. counter panel
15.0W
E
“L HPOW”
25.0W
M
PTT : ON
2) “L2 HPOW”
PTT : ON
3) “C HPOW”
PTT : ON
4) “H2 HPOW”
PTT : ON
5) “H HPOW”
PTT : ON
4. Low power
1) Set test mode
Power meter
5.0W
±
0.5W
Select “LPOW” in tuning mode.
“L LPOW”
PTT : ON
2) “L2 LPOW”
PTT : ON
3) “C LPOW”
PTT : ON
4) “H2 LPOW”
PTT : ON
5) “H LPOW”
PTT : ON
5. Power check 1) Set test mode
Power meter
ANT
Check
10W
±
1W, 6A or less
K
CH : CH1 - Sig1
15W
±
1W, 6A or less
E
CH2 - Sig1
Ammeter
DC IN
25W
±
1W, 8A or less
M
CH3 - Sig1
PTT : ON
6. Modulation
1) Set test mode
Power meter Rear
ANT
Make the de-
balance
MIC input : OFF
Deviation
panel
modulation
Select “BAL” in tuning mode. meter
waveform near.
“L BAL”
Oscilloscope
Deviation meter filter
LPF : 3kHz
AF VTVM
Front
MIC
HPF : OFF
AG
panel
De-emphasis : OFF
2) “C BAL”
PTT : ON
3) “H BAL”
PTT : ON
7. Maximum
1) Set test mode
2.05kHz
+0Hz/–50Hz
deviation
Connect AG to the MIC
(According to the
terminal.
, –)
Select “MAX” in tuning mode.
“L MAX”
AG : 1kHz/40mV
Deviation meter filter
LPF : 15kHz
HPF : OFF
De-emphasis : OFF
PTT : ON
2) “C MAX”
PTT : ON
3) “H MAX”
PTT : ON
Содержание TK-785
Страница 69: ...TK 785 TK 785 TK 785 BLOCK DIAGRAM K E 95 ...
Страница 70: ...TK 785 TK 785 TK 785 96 BLOCK DIAGRAM M ...