TK-5310
60
•Narrow
3) Adj item:[N Squelch(1)]
SSG
Panel
ANT
Panel
After input
After adjusting SQL,
(Concentric SW:B)
Adjust:[***]
AF VTVM
Universal
signal from SSG, check SQL open/Close.
4) Adj item:[NL Squelch(1)]
t
Oscilloscope
connector
press [B] key.
[Panel test mode]
[NC Squelch(1)]
t
[NH Squelch(1)]
That numeric
1) CH-Sig:1-1
Adjust:[***]
will be stored
SSG 12dB SINAD level
SSG output:12dB SINAD level -4dB
in memory.
-1.5dB:Open
(MOD:1kHz/±1.5kHz)
SSG -130dBm(0.07
µ
V):Close
•P25
5) Adj item:[A Squelch(1)]
2) CH-Sig:2-1
(Concentric SW:C)
Adjust:[***]
SSG 12dB SINAD level
6) Adj item:[AL Squelch(1)]
t
-1.5dB:Open
[AC Squelch(1)]
t
[AH Squelch(1)]
SSG -130dBm(0.07
µ
V):Close
Adjust:[***]
3) CH-Sig:3-1
SSG output:12dB SINAD level (Wide)
SSG 12dB SINAD level
*Set to the SSG output level
-1.5dB:Open
that 12dB SINAD is obtained
SSG -130dBm(0.07
µ
V):Close
at Wide.
(MOD:1kHz/±3kHz)
5. Squelch
1) Adj item:[W Squelch(9)]
After adjusting SQL,
(Tight)
Adjust:[***]
check SQL open/close.
adjust
2) Adj item:[WL Squelch(9)]
t
[Panel test mode]
•Wide
[WC Squelch(9)]
t
[WH Squelch(9)]
1) CH-Sig:1-1
(Concentric SW:A)
Adjust:[***]
SSG 12dB SINAD level
SSG output:12dB SINAD level +6dB
+8dB:Open
(MOD:1kHz/±3kHz)
SSG 12dB SINAND level
:Close
2) CH-Sig:2-1
SSG 12dB SINAD level
+8dB:Open
SSG 12dB SINAD level
:Close
3) CH-Sig:3-1
SSG 12dB SINAD level
+8dB:Open
SSG 12dB SINAD level
:Close
•Narrow
3) Adj item:[N Squelch(9)]
After adjusting SQL,
(Concentric SW:B, C)
Adjust:[***]
check SQL open/close.
SSG output:12dB SINAD level +6dB
[Panel test mode]
(MOD:1kHz/±1.5kHz)
1) CH-Sig:1-1
SSG -112dBm(0.562
µ
V):Open
SSG -116dBm(0.35
µ
V):Close
2) CH-Sig:2-1
SSG -112dBm(0.562
µ
V):Open
SSG -117dBm(0.32
µ
V):Close
3) CH-Sig:3-1
SSG -112dBm(0.562
µ
V):Open
SSG -117dBm(0.32
µ
V):Close
Measurement
Adjustment
Item
Condition
Test-
Unit
Terminal
Unit
Parts
Method
Specifications/Remarks
equipment
ADJUSTMENT
Содержание TK-5310