TK-5310
42
• Key operation
Key
Function
Display
[Selector]
Test frequency channel up/down Channel No.
[Concentric switch] Channel spacing switching
Wide :"W"
(Position "A":Wide,
Narrow :"N"
Position "B":Narrow,
P25 :"A"
Position "C":P25)
[Lever switch] RF output power switching
Low power :"LO"
(
_
:Low power,
-
:High power) High power :"HI"
[PTT]
Transmit
-
[Side1]
Squelch level change
Squelch level 0:"SQ.LV0"
(0
t
1
t
2
t
• • •
t
9
t
0
t
1
t
2
t
• • •
)
Squelch level 1:"SQ.LV1"
Squelch level 9:"SQ.LV9"
[Side1] Hold
Squelch off
[Side2]
MSK baud rate change
2400bps:
icon
(1200bps/2400bps)
appears
[Side2] Hold
Compander on/off
On:
icon appears
[Side3]
Shifts to the Panel tuning mode -
[Side3] Hold
LCD all lights
LCD all point appears
[Orange]
Beat shift on/off
On:
icon appears
[A]
Unused
-
[B]
Unused
-
[C]
Test signaling down
Signaling No.
[D]
Test signaling up
Signaling No.
[0] to [9] and
Use as the DTMF keypad.
-
[#], [*]
If a key is pressed during transmission,
the DTMF corresponding to the
key that was presses is sent.
• LED indicator
Red LED
Lights during transmission. Blinks at the low
battery voltage warning.
Green LED
Lights when there is carrier.
• LCD display in the panel test mode
• Filter Mode
Display
Condition
Key
W
WIDE (25kHz) Filter
Concentric switch "A"
N
NARROW (12.5kHz) Filter
Concentric switch "B"
A
P25 (12.5kHz) Filter
Concentric switch "C"
ADJUSTMENT
A
B
C
6
MIC
Volume
Selector
Side 1 key
Side 2 key
PTT switch
Concentric Switch
Lever switch
Orange key
Universal
connector
Side 3 key
Controls
Panel Test Mode
(K2, K3, K5 and K6 models only)
For the K, K4 models (without LCD), perform "Test mode"
using the KPG-95D.
■
Test mode operation features
This transceiver has a test mode.
To enter panel test
mode, press and hold the [Side3] and [PTT] keys while
turning the transceiver power on and then the [PTT] key
first.
Test mode can be inhibited by programming. To exit
test mode, switch the power on again.
• When the panel test mode is activated, the channel se-
lected with the [Selector] knob and the last used signaling
number are displayed. When it is activated for the first
time, the signaling number is 1.
• If test signaling 20 (Tone Test Pattern) is selected, the re-
sult of Bit Error Rate (BER) calculation is displayed on the
LCD. The BER value is also output from the serial port.
• The P25 and analog modes are switched automatically by
selecting test signaling. When P25 mode is effective, “A”
is displayed on the LCD.
LO
W
1
-
1
[ None
]
SQ. LV
1
Channel No.
Signaling No.
W : Wide
N : Narrow
A : P25