TH-D72A/D72E
51
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
9. CTCSS
Deviation
Switch to Service Setup mode
and carry out the operations for
item J.
Linear detector (FM p-p/2)
LPF:
3kHz
HPF:
OFF
De-emphasis:
OFF
1) Frequency: 146.100MHz
K
145.100MHz
E
Transmission
Power
meter
Linear
detector
Oscillo-
scope
ANT
Tuning
control
[
X
]
Write
0.75kHz±50Hz
2) Frequency: 136.100MHz
Transmission
3) Frequency: 173.900MHz
Transmission
9. CTCSS
Deviation
4) Frequency: 444.100MHz
K
435.100MHz
E
Transmission
Power
meter
Linear
detector
Oscillo-
scope
ANT
Tuning
control
[
X
]
Write
0.75kHz±50Hz
5) Frequency: 410.100MHz
Transmission
6) Frequency: 469.900MHz
Transmission
10. DCS Devia-
tion
Switch to Service Setup mode
and carry out the operations for
item K.
Linear detector (FM p-p/2)
LPF:
3kHz
HPF:
OFF
De-emphasis:
OFF
1) Frequency: 146.100MHz
K
145.100MHz
E
Transmission
Power
meter
Linear
detector
Oscillo-
scope
ANT
Tuning
control
[
X
]
Write
0.75kHz±50Hz
2) Frequency: 136.100MHz
Transmission
3) Frequency: 173.900MHz
Transmission
4) Frequency: 444.100MHz
K
435.100MHz
E
Transmission
5) Frequency: 410.100MHz
Transmission
6) Frequency: 469.900MHz
Transmission
11. VOX Sensi-
tivity Write
Switch to Service Setup mode
and carry out the operations for
item L.
1) Frequency: 144.100MHz
VOX1
AG:
1kHz/80mV
AG
MIC
[
X
]
Write
2) Frequency: 144.100MHz
VOX9
AG:
1kHz/2mV
Write