TH-D72A/D72E
43
• N. S-meter/Squelch
1) Display the “V SM/SQ A” item.
2) Select “SQ1” item after press [
X
OK] key at “V SM/SQ
A” item.
3) Press [
X
OK] key to set the “adjustment value” in the
EEPROM as a threshold value.
4) Select “SQ2” item.
5) Press [
X
OK] key to set the “adjustment value” in the
EEPROM as a level 2 value.
6) Select “SM1” item.
7) Press [
X
OK] key to set the “adjustment value” in the
EEPROM as the fi rst segment ON value.
8) Select “SM FULL” item.
9) Press [
X
OK] key to set the “adjustment value” in the
EEPROM as all-segment ON value.
M
S
S
V
0
0
0
0
1
EEPROM setting
adjustment value
/
0 0
1
1
1
Q
S
SQ
t
A
A
1
• Perform Item N about “U SM/SQ A”, “V SM/SQ B” and
“U SM/SQ B”.
• To terminate the Service Setup mode, turn the power
supply OFF.
ADJUSTMENT
CN769
LCD CONTRAST
TX-RX UNIT (A/3)
Foil side
TX-RX UNIT (C/3)
Foil side
TX-RX UNIT (A/3)
Component side
TX-RX UNIT (C/3)
Component side
CN714
32K
CV_A
CN641
BATT+
CN642
BATT–
CV_B
LO2_A
J641
DC-IN
CN204
ANT
BATT+
BATT–
J701
EXT. MIC / EXT. SP
J703
USB
J702
COM
CN714: RTC frequency adjust
CN769: LCD contrast
CV_A: VCO Lock Voltage (A-band)
CV_B: VCO Lock Voltage (B-band)
LO2_A: 2nd local
Adjustment Points