TH-D72A/D72E
50
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
6. MAX Devia-
tion
4) Frequency: 444.100MHz
K
435.100MHz
E
Transmission
Oscillo-
scope
Linear
detector
Power
meter
AG
ANT
Tuning
control
[
X
]
Write
4.2kHz±100Hz
5) Frequency: 410.100MHz
Transmission
6) Frequency: 469.900MHz
Transmission
7. Balance 1
Switch to Service Setup mode
and carry out the operations for
item H.
Linear detector (FM p-p/2)
LPF:
15kHz
HPF:
OFF
De-emphasis:
OFF
1) Frequency: 146.100MHz
K
145.100MHz
E
Transmission
Power
meter
Linear
detector
Oscillo-
scope
ANT
Tuning
control
[
X
]
Write
2.4kHz±50Hz
2) Frequency: 136.100MHz
Transmission
3) Frequency: 173.900MHz
Transmission
4) Frequency: 444.100MHz
K
435.100MHz
E
Transmission
5) Frequency: 410.100MHz
Transmission
6) Frequency: 469.900MHz
Transmission
8. Balance 2
Switch to Service Setup mode
and carry out the operations for
item I.
Linear detector (FM p-p/2)
LPF:
15kHz
HPF:
OFF
De-emphasis:
OFF
1) Frequency: 146.100MHz
K
145.100MHz
E
Transmission
Power
meter
Linear
detector
Oscillo-
scope
ANT
Tuning
control
[
X
]
Write
2.4kHz±50Hz
2) Frequency: 136.100MHz
Transmission
3) Frequency: 173.900MHz
Transmission
4) Frequency: 444.100MHz
K
435.100MHz
E
Transmission
5) Frequency: 410.100MHz
Transmission
6) Frequency: 469.900MHz
Transmission