NX-200
51
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
10. Single
Tone
Deviation
adjust
*4
[Narrow]
1) Adj item: [An TONE]
Adjust:
[
✳✳✳✳
]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [Single
Tone Deviation
(Analog Narrow)]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
Press
[Transmit] button.
Press
[Apply]
button to store the
adjustment
value.
Deviation
meter
Oscilloscope
Panel
ANT
Panel
[Panel
tuning
mode]
[
],
[
]
[PC test
mode]
[ ],[ ]
Write the value as
followings.
513 (Reference
value)
1.50kHz±0.05kHz
[Wide]
1) Adj item: [Aw TONE]
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [Single
Tone Deviation
(Analog Wide)]
PTT:
Press
[Transmit] button.
Press
[Apply]
button to store the
adjustment
value.
3.00kHz±0.05kHz
11. MSK
Deviation
adjust
*4
[Narrow]
1) Adj item: [An MSK]
Adjust:
[
✳✳✳✳
]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [MSK Devia-
tion (Analog Narrow)]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
Press
[Transmit] button.
Press
[Apply]
button to store the
adjustment
value.
Write the value as
followings.
513 (Reference
value)
1.50kHz±0.05kHz
[Wide]
1) Adj item: [Aw MSK]
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [MSK Devi-
ation (Analog Wide)]
PTT:
Press
[Transmit] button.
Press
[Apply]
button to store the
adjustment
value.
3.00kHz±0.05kHz
12. CWID
Deviation
adjust
*4
[Very
Narrow]
1) Adj item: [Nv CWID]
Adjust:
[
✳✳✳✳
]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [CW ID
Deviation (NXDN
Very Narrow)]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
Press
[Transmit] button.
Press
[Apply]
button to store the
adjustment
value.
Write the value as
followings.
376 (Reference
value)
1.10kHz±0.10kHz
*4: Refer to the “Necessary Deviation adjustment item for each signaling and mode” table on pages 52 and 53.
13. VOX1
adjust
1) Adj item: [VOX1]
Adjust:
[
✳✳✳
]
AG: 1kHz/45mV at
MIC terminal
1) Adj item: [VOX1]
AG: 1kHz/45mV at
MIC terminal
AG
Panel
Universal
connector
[Panel tuning mode]
After apply signal
from AG, press [ ]
key to store the
adjustment value.
[PC test mode]
After apply signal
from AG, press
[Apply] button to
store the adjust-
ment value.
14. VOX10
adjust
1) Adj item: [VOX10]
Adjust:
[
✳✳✳
]
AG: 1kHz/3mV at
MIC terminal
1) Adj item: [VOX10]
AG: 1kHz/3mV at
MIC terminal