![Kenwood NEXEDGE NXR-810 Скачать руководство пользователя страница 80](http://html.mh-extra.com/html/kenwood/nexedge-nxr-810/nexedge-nxr-810_service-manual_192292080.webp)
NXR-810
80
ADJUSTMENT
Transmitter Section
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
1. High Trans-
mit Power
Limit Adjust
FPU Test mode
1) Adjust Item: [High Transmit
Power Limit Adjust]
Frequency: [Low], [Low’],
[Center], [High’], [High]
Press [Transmit] button.
Power meter Rear
TX ANT
PC
ADJ
43W±1.5W
Press [Apply] button to store
the adjustment value.
2. High Trans-
mit Power
Adjust
FPU Test mode
1) Adjust Item: [High Transmit
Power]
Frequency: [Low], [Low’],
[Center], [High’], [High]
Press [Transmit] button.
40W±0.5W
3. Low Trans-
mit Power
Limit Adjust
FPU Test mode
1) Adjust Item: [Low Transmit
Power Limit Adjust]
Frequency: [Low], [Low’],
[Center], [High’], [High]
Press [Transmit] button.
28W±1.5W
4. Low Trans-
mit Power
Adjust
FPU Test mode
1) Adjust Item: [High Transmit
Power Adjust]
Frequency: [Low], [Low’],
[Center], [High’], [High]
Press [Transmit] button.
5W±0.5W
5. Maximum
Deviation
Adjust
[NXDN
Nar-
row]
FPU Test mode
1) Adjust Item: [Maximum De-
viation (NXDN Narrow)]
PC
ADJ
Write the value as
followings (typical
value)
[Maximum Deviation
(NXDN Narrow)] =
530
Press [Apply] button to store
the adjustment value.
6. Maximum
Deviation
Adjust
[NXDN
Very
Narrow]
FPU Test mode
1) Adjust Item: [Maximum De-
viation (NXDN Very Narrow)]
Write the value as
followings (typical
value)
[Maximum Deviation
(NXDN Very Nar-
row)] = 530
7. Maximum
Deviation
Adjust
[Analog
Wide]
FPU Test mode
1) Adjust Item: [Maximum De-
viation (Analog Wide)]
Write the value as
followings (typical
value)
[Maximum Deviation
(Analog Wide)] =
530
8. Maximum
Deviation
Adjust
[Analog
Nar-
row]
FPU Test mode
1) Adjust Item: [Maximum De-
viation (Analog Narrow)]
Write the value as
followings (typical
value)
[Maximum Deviation
(Analog Narrow)] =
530