![Kenwood NEXEDGE NXR-810 Скачать руководство пользователя страница 74](http://html.mh-extra.com/html/kenwood/nexedge-nxr-810/nexedge-nxr-810_service-manual_192292074.webp)
NXR-810
74
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
6. Open
Squelch
Adjust
[Analog
Nar-
row]
FPU Test mode
1) Adjust Item: [Open Squelch
(Analog Narrow)]
Connect the SSG to the RX
ANT.
SSG
setting
Frequency: [Low], [Low’],
[Center], [High’], [High]
Output
: 12dB SINAD level –1dB
MOD: 1.0kHz
DEV: ±1.5kHz
SSG
Audio
analyzer
Oscilloscope
Rear
RX ANT
PC
ADJ
Press [Apply] button to store
the adjustment value.
Note:
Write the fi xed value of “30”
when the adjustment value is
24 or less.
2) SSG output: OFF
Check
The squelch shall be closed.
7. Open
Squelch
Adjust
[NXDN
Very
Narrow]
FPU Test mode
1) Adjust Item: [Open Squelch
(NXDN Very Narrow)]
Connect the SSG to the RX
ANT.
SSG
setting
Frequency: [Low], [Low’],
[Center], [High’], [High]
Output: 12dB SINAD level
for Analog Narrow –4dB
MOD: OFF
PC
ADJ
Press [Apply] button to store
the adjustment value.
8. Tight
Squelch
Adjust
[Analog
Wide]
FPU Test mode
1) Adjust Item: [Tight Squelch
(Analog Wide)]
Connect the SSG to the RX
ANT.
SSG
setting
Frequency: [Low], [Low’],
[Center], [High’], [High]
Output
: 12dB SINAD level +8dB
MOD: 1.0kHz
DEV: ±3.0kHz
PC
ADJ
Press [Apply] button to store
the adjustment value.
2) SSG output: OFF
Check
The squelch shall be closed.
9. Tight
Squelch
Adjust
[Analog
Nar-
row]
FPU Test mode
1) Adjust Item: [Tight Squelch
(Analog Narrow)]
Connect the SSG to the RX
ANT.
SSG
setting
Frequency: [Low], [Low’],
[Center], [High’], [High]
Output
: 12dB SINAD level +8dB
MOD: 1.0kHz
DEV: ±1.5kHz
PC
ADJ
Press [Apply] button to store
the adjustment value.
2) SSG output: OFF
Check
The squelch shall be closed.